Direct Heat CO2 Incubator EZL-CI84 Catalog

Description

EziLab’s Direct Heat CO2 Incubator EZL-CI84 heats an 80L chamber from RT+5 to 60C with CO2 control from 0 to 20% and temperature stability within 0.3C, using a direct heating system with dual jacket insulation for faster temperature recovery after door openings. Microcomputer touch control, PID concentration regulation, and a CO2 sensor with 0.1% control keep culture conditions steady, while UV sterilization and a testing hole support routine monitoring without opening the chamber. Two standard shelves, expandable to ten, hold growing sample loads at 600W power draw. As a tissue culture incubator built for fast recovery cycles, this unit suits labs running frequent door access during active culture work. Stem cell and tissue culture research groups use it where quick temperature and CO2 recovery after handling protects sensitive cell lines, while pharmaceutical and biomedical testing laboratories rely on the same co2 incubator platform for routine assay incubation. Research incubation applications spanning microbiology and cell biology benefit from the compact 80L footprint on shared lab bench space. Academic labs running multiple short protocols each day favor a lab incubator with this recovery speed. Frequent door access makes the case for fast recovery, so check the Laboratory Incubator page for jacketed alternatives and the Direct Heat CO2 Incubator page for this format.

Specifications

Chamber Volume 80 L
Temperature Range RT+5 to 60℃
Temperature Stability < ± 0.3°C
Temperature Uniformity < ± 1 °C
CO2 Range 0 to 20 %
CO2 Control Accuracy ±0.1% (imported sensor)
Humidity Method Natural Vaporization
Testing hole on the inner door Φ 16mm
Operating Temperature +18 to 30℃
Perforated shelf (Std/Max) 2/10
Power Rating 600 W
Chamber Size (W×D×H) 410 × 440 × 510 mm
Exterior Size((W×D×H) 560 × 640 × 900 mm

Features

Feature AreaDescription
Chamber80 L chamber volume with 2 perforated shelves as standard, up to 10 at maximum.
TemperatureRT+5 to 60 °C temperature range with a direct heating system and dual jacket insulation.
CO2CO2 range of 0 to 20% with PID concentration regulation.
ControlMicrocomputer touch control.
Sterilization and AccessUV sterilization chamber with a Φ16 mm testing hole on the inner door.

Applications

  • Applied by stem cell labs for tissue culture in the 80 L direct heat chamber.
  • Employed by pharmaceutical teams for assay incubation at 0 to 20% CO2.
  • Suited to biomedical labs running cell biology work from RT+5 to 60 °C.
  • Supports microbiology groups that open the door often, using dual jacket insulation.
  • Handles frequent sampling checks through the Φ16 mm inner door test hole.
  • Fits multi-protocol benches that load 2 shelves, expandable to 10.