Description
EziLab offers the Low Speed Centrifuge EZL-LSC112, a benchtop clinical centrifuge that spins twenty-four 15 mL tubes at up to 4,000 rpm and 2,680 g for routine sedimentation. Speed holds to ±10 rpm, the timer adjusts from 0 to 99 minutes, and an LCD shows set and actual values. Noise stays at or under 55 dB(A), quiet enough for a shared clinic bench, the 430 by 320 mm footprint leaves room for other instruments, and the 18 kg body moves between rooms. Lid interlock and imbalance detection stop the drive before damage spreads, and the sealed chamber wipes clean after spills. Hospital laboratories, outpatient clinics, blood collection centers, veterinary practices, university cell culture rooms and diagnostic test centers use this low speed centrifuge for the daily separations that need neither cooling nor high g. Typical runs include serum and plasma separation from blood tubes, urine sediment preparation, cell pelleting after culture, body fluid clarification, protein and nucleic acid precipitate collection and sample clean-up before analyzers. Choose it over a refrigerated unit when samples are processed within minutes of collection. Gel separator tubes list a required force and spin time; compare those figures with the 2,680 g maximum here before assuming a match. Other rotor counts can be reached from Laboratory Centrifuge by way of Low Speed Centrifuge.
Specifications
| Maximum Speed | 4000rpm |
|---|---|
| Maximum RCF | 2680 × g |
| Maximum Capacity | 24 × 15 ml |
| Timer Range | 0 to 99 min adjustable |
| Speed Accuracy | ±10 r/min |
| Noise Level | Less than equal to 55 dB(A) |
| Dimensions (W×D×H) | 430 × 320 × 250 mm |
| Wight (without rotor) | 18Kg |
Features
| Feature Area | Description |
| LCD | An LCD shows set and actual values side by side. |
| Lid Interlock | A lid interlock keeps the lid shut while the rotor spins. |
| Imbalance Detection | Imbalance detection watches the load during a run. |
| Rotor Options | Angle rotors and adapters take tubes from microtubes to larger culture tubes. |
| Benchtop Body | A compact benchtop body fits tight bench space. |
Applications
Rotor Selection
Rotor Type | Capacity (ml) | Maximum Speed (r/min) | Maximum RCF (×g) |
Angle Rotor 01 | 12 × 10/5 mL | 4000 r/min | 2680 × g |
Angle Rotor 02 | 12 × 20/5 mL | 4000 r/min | 2680 × g |
Angle Rotor 03 | 18 × 10/5 mL | 4000 r/min | 2680 × g |
Angle Rotor 04 | 4 × 50 mL | 4000 r/min | 2680 × g |
Adapter Selection
Adapter Type | Capacity (ml) | Maximum Speed (r/min) | Maximum RCF (×g) |
Adapter 01 | 12 × 2mL | 4000 r/min | 2680 × g |
Adapter 02 | 12 × 2mL | 4000 r/min | 2680 × g |
Adapter 03 | 18 × 2mL | 4000 r/min | 2680 × g |
Adapter 04 | 18 × 1.5mL | 4000 r/min | 2680 × g |
Adapter 05 | 4 × 15/10 mL | 4000 r/min | 2680 × g |
Adapter 06 | 4 × 5/2 mL | 4000 r/min | 2680 × g |