Low Speed Refrigerated Centrifuge EZL-LRC108 Catalog

Description

EziLab offers the Low Speed Refrigerated Centrifuge EZL-LRC108, a bulk centrifuge that spins six 1000 mL bottles at up to 8000 rpm and 11180 RCF while a direct-drive motor holds speed within ±10 rpm. A touch screen sets runs, the timer covers 1 second to 99 minutes 59 seconds, refrigeration cools heat-sensitive loads, a lid lock keeps the chamber closed, and noise stays at 62 dB(A) or below. Fixed angle rotors take 6 by 500 mL at 8000 rpm or 6 by 1000 mL at 7000 rpm, sealed options are available, and the 860 by 730 by 1200 mm cabinet draws 6500 W and weighs 270 kg. Choose it over the 5000 rpm and 5500 rpm siblings when bottle runs need more force. Industrial labs, hospitals and pharmaceutical laboratories need large batches cooled during the spin, so samples stay viable and total runs drop, with sealed rotors keeping biosafety work contained. Typical uses include clinical sample preparation, bulk serum and plasma separation, culture harvesting, and lysate clarification. Ask which containment rating the sealed rotor lids carry; lower-speed chilled siblings are filed under Laboratory Centrifuge and Low Speed Refrigerated Centrifuge.

Specifications

Maximum Speed 8000rpm
Maximum RCF 1180×g
Maximum Capacity 6×1000 ml
Timer Range 1 s to 99 min 59 s
Speed Accuracy ±10 rpm
Noise Level Less than equal to 62 dB(A)
Power 6500 W
Dimensions (W×D×H) 860×730×1200 mm
Net Weight 270 kg

Features

Feature AreaDescription
DriveDirect-drive motor system for bulk spinning of large bottles.
RotorsFixed-angle bottle rotors, with sealed rotor options available.
RefrigerationBuilt-in cooling for temperature-sensitive loads with a fast pre-cooling feature.
ControlsTouch-screen interface with a wide timer range, pre-set programs and memory recall that cuts repeat setup.
Cabinet & LidLid lock that keeps the chamber closed during operation, in a large floor-standing cabinet with corrosion-resistant construction.

Applications

  • Supports clinical sample preparation in hospitals.
  • Handles bulk serum and plasma separation in clinical labs.
  • Suited to culture harvesting in research and high-throughput labs.
  • Applied to lysate clarification in pharmaceutical laboratories.
  • Employed for cooling heat-sensitive samples during bottle runs in industrial labs.

Rotor Selection

Rotor Type 

Capacity (ml) 

Maximum Speed (r/min) 

Maximum RCF (×g) 

Fixed Angle Rotor 01

6 × 500 ml 

8000r/min

11880×g 

Fixed Angle Rotor 02

6 × 1000 ml 

7000r/min

11630×g