Water Jacket CO2 Incubator EZL-WJ81 Catalog

Description

EziLab’s Water Jacket CO2 Incubator EZL-WJ81 heats an 80L chamber from RT+3 to 60C with CO2 control from 0 to 20% and temperature stability within 0.2C, using stable water jacket heating and natural vaporization humidification to limit temperature swings air-jacketed units see during door openings. UV sterilization with HEPA filtration, automatic door response control, and a triple safety alarm system protect long runs, while two adjustable shelves, expandable up to nine, fit growing culture loads at 600W. As a laboratory incubator built for continuous cell and tissue culture work, this unit recovers CO2 and temperature setpoints quickly after routine access. Cell and tissue culture laboratories use it for mammalian cell lines that need stable, low-drift conditions over multi-day growth cycles, while pharmaceutical industries rely on the same cell culture incubator platform for bioprocess development and cell line banking. Research centers apply it to primary cell and stem cell work where temperature swings affect viability, and hospitals use it for diagnostic cell culture ahead of pathology workups. Core facilities running shared equipment favor a tissue culture incubator of this stability for sensitive protocols. Water jacket or direct heat? Recovery speed against drift is the question, and the Laboratory Incubator and Water Jacket CO2 Incubator pages cover both.

Specifications

Chamber Volume 80 L
Temperature Range RT +3 to 60°C
Temperature Stability ≤ ±0.2°C
Temperature Uniformity ≤ ±0.3°C
Timing Range 1 to 999 Minutes or Without Timing
CO2 Range 0 to 20%
Humidity Method Natural Vaporization
Power Rating 600 W
Chamber Dimension (W×D×H) 40×40×50 cm
Exterior Dimension (W×D×H) 57×59×93 cm
Package Dimension (W×D×H) 64×68×103 cm
Net Weight 55 kg
Gross Weight 85 kg

Features

Feature AreaDescription
Chamber80 L chamber of 40 × 40 × 50 cm, with 2 shelves that can be expanded to nine.
TemperatureRT +3 to 60 °C temperature range with water jacket heating.
CO2 and HumidityCO2 range of 0 to 20% with a natural humidification system using natural vaporization.
TimerTiming range of 1 to 999 minutes, or operation without timing.
Contamination Control and AlarmsUV sterilization with HEPA filtration, automatic door response control and a triple safety alarm system.

Standard Accessories

  • Shelf- 2Pcs

Applications

  • Applied by cell culture labs for mammalian cell lines at RT+3 to 60 °C with 0 to 20% CO2.
  • Employed by stem cell groups for primary and stem cell work in the 80 L chamber.
  • Suited to pharmaceutical teams for cell line banking with UV and HEPA filtration.
  • Supports hospital diagnostic culture runs on a 1 to 999 min timer.
  • Handles cancer cell metabolism studies on 2 shelves expandable to 9.
  • Fits shared core facilities that need a triple safety alarm system.