Description
EziLab offers the Gas Chromatography Mass Spectroscopy EZL-GCMS102, a quadrupole EI CI GC-MS that pairs a programmable GC oven with a mass detector that switches between electron ionization and positive or negative chemical ionization. The column oven spans RT +4 °C to 450 °C with ≤ ±0.1 °C control, 32 heating ramps up to 120 °C/min and cooling from 450 to 50 °C in 6 minutes, cutting cycle time. Two ultra-deactivated inlets run split, splitless and pulsed modes with electronic pressure control to ±0.001 psi and split ratios to 12,500:1. On the MS side, a molybdenum quadrupole with pre-rods covers 1.5–1200 u at 20,000 u/s, while a long-life channel electron multiplier delivers 1 pg OFN at S/N ≥ 2000:1 in EI and 200 fg OFN in NCI. An 8-inch Android touchscreen adds self-diagnosis and leak detection. Forensic, environmental, pharmaceutical, polymer and food testing laboratories use this GC-MS for trace-level compound identification. Uses cover drug residue confirmation, VOC and pesticide screening, metabolite profiling and polymer additive analysis. Choose it over EI-only systems when electronegative analytes need NCI sensitivity. Line it up against sibling models in the GC MS category, or open the Gas Chromatography Mass Spectroscopy page to review all parameters.
Specifications
| Retention time repeatability | < 0.008% |
|---|---|
| Peak area repeatability | < 0.5% |
| Display | 8-inch high-resolution capacitive touchscreen |
| User interface | Android-based graphical interface with self-diagnosis & leakage detection |
| Column oven temperature range | RT +4°C to 450°C |
| Temperature accuracy | ≤ ±0.1°C |
| Heating gradients | 32 |
| Constant temperature platforms | 33 |
| Maximum heating rate | ≥ 120°C/min |
| Cooling rate | 450°C to 50°C in 6 min |
| Ambient temperature sensitivity | < 0.01°C per 1°C change |
| Pressure accuracy | ±0.001 psi |
| Carrier/makeup gas types | N₂, He, H₂, Ar |
| Flow stability | < 1%/10 min |
| Injection ports | Up to 2 |
| Injection modes | Split, splitless, pulse split, pulse splitless |
| Column compatibility | 0.1–0.53 mm ID |
| Maximum split ratio | 12500:1 |
| Injection port temperature | Up to 450°C |
| Gas saving mode | Yes |
| Septum purge | Electronic control |
| Flow range | 0–500 mL/min (N₂), 0–1250 mL/min (H₂/He) |
| Injection port surface | Ultra-deactivated |
| Transfer-line temperature | 50–400°C |
| Ion source type | Dual-filament EI source |
| Ionization modes | Positive & negative CI |
| Emission current | 0–300 μA |
| Ionization energy | 0–240 eV |
| Ion source temperature | 50–350°C |
| Cleaning gas flow | 0–5 sccm |
| Quadrupole material | High-precision molybdenum |
| Pre-rod design | Yes |
| Mass range | 1.5–1200 u |
| Mass resolution | 0.6–0.8 amu |
| Mass stability | ±0.10 u/48h |
| EI sensitivity | 1 pg OFN, S/N ≥ 2000:1 |
| SIP sensitivity | 100 fg OFN, S/N ≥ 300:1 |
| NCI sensitivity | 200 fg OFN, S/N ≥ 2000:1 |
| PCI sensitivity | 100 pg BZP, S/N ≥ 1200:1 |
| Maximum scan speed | 20000 u/s |
| Maintenance access | Side-opening design |
| Detector type | Long-life channel EM |
| Ion path | Triaxial |
| Dynamic range | ≥ 10⁷ |
| Vacuum pump system | Mechanical + turbo pump (250 L/s He) |
| Vacuum lock performance | 10⁻⁴ Pa in 20 min, maintains vacuum during outages |