Description
EziLab offers the Ion Chromatograph EZL-IC65, an ion chromatography system that separates anions or cations on an exchange column and measures them by conductivity, with on-line eluent generation removing manual eluent prep. A high-pressure pump reaches 42 MPa and delivers 0.001–9.999 mL/min, while the generator produces KOH or MSA eluent from 0.1 to 100 mM for isocratic or gradient runs. The ≤0.8 µL conductivity cell reads 0–50,000 µS/cm with 0.02 nS electronic noise, so trace ions and high-salt samples run on one platform. Eluent pre-heating steadies baselines, a built-in gas-liquid separator strips bubbles, and real-time cartridge level sensing warns before reagent runs out. An intelligent leak alarm, automatic start-up and shut-down, and an HD touchscreen showing the live flow path simplify unattended operation. Environmental agencies, disease control centers, food producers, electronics plants, mining companies and pharmaceutical labs use this ion chromatograph for routine ion quantification. Typical analyses include fluoride, chloride, nitrate and sulfate in drinking water, nitrite in cured meats, ultrapure rinse water checks, leach liquor profiling and counterion assays. Choose it over manual-eluent IC when gradient reproducibility and lower reagent handling matter. Compare other configurations under Ion Chromatographs, or go to the Ion Chromatograph page for its spec table.
Specifications
| Cell Volume | ≤0.8 µL |
|---|---|
| Detection Range | 0 to 50000 µS/cm |
| Detection Resolution | ≤0.0020 ns/cm |
| Electronic Noise | 0.02 ns |
| Pump Maximum Pressure | 42 MPa |
| Pressure Display Accuracy | ≤0.1 MPa |
| Flow Rate Range | 0.001 to 9.999 mL/min |
| Detector Maximum Pressure | 10.0 MPa |
| Eluent Type | KOH/MSA |
| Eluent Concentration Range | 0.1 to 100 mM |
| Gradient Accuracy | 0.002 |
| Pressure | 0.1 – 5.0 mL/min |
| Power Requirement | ≤ 30 MPa |
| Dimension (L×W×H) | 150 W |
| Net Weight | 500×360×550 mm |
| Gross Weight | 32 Kg |
Features
| Feature Area | Description |
| Online Eluent Generation | Eluent is generated online, removing manual eluent preparation. |
| Eluent Pre-Heating | Eluent pre-heating works with built-in temperature control. |
| Leak & Eluent Monitoring | Leak detection with an alarm pairs with real-time detection of remaining eluent in the cartridge. |
| Gas-Liquid Separator | A built-in gas-liquid separator sits inside the system. |
| Touchscreen & Startup | A touchscreen displays the flow path, with automatic startup and shutdown. |