EziLab Ion Chromatograph EZL-IC65 operates with gradient elution methods using KOH or NaOH eluent generation and pump pressure reaching 42MPa, delivering an advanced gradient elution ion chromatograph built for precise ionic separation across wide analytical ranges. Gradient accuracy across elution cycles improves analytical repeatability, enabling consistent identification of ionic species in complex matrices without recalibration between sequential runs. The 42MPa pump pressure maintains stable flow throughout extended analytical sessions, preventing pressure deviation and ensuring reproducible separation across high-throughput sample batches. Digital flow control supports parameter adjustment for eluent concentration and flow rate, reducing operator intervention during routine analytical workflows. The compact system layout fits analytical laboratory environments with minimal bench space, supporting installation alongside existing instrumentation without workflow disruption. This ion chromatograph serves environmental monitoring agencies, food safety testing facilities, metallurgy laboratories, electronics manufacturing units, and chemical research facilities. Explore EziLab's full range of ion chromatographs and analytical instruments for related requirements.



Cell Volume ≤0.8 µL
Detection Range 0 to 50000 µS/cm
Detection Resolution ≤0.0020 ns/cm
Electronic Noise 0.02 ns
Pump Maximum Pressure 42 MPa
Pressure Display Accuracy ≤0.1 MPa
Flow Rate Range 0.001 to 9.999 mL/min
Detector Maximum Pressure 10.0 MPa
Eluent Type KOH/MSA
Eluent Concentration Range 0.1 to 100 mM
Gradient Accuracy 0.002
Pressure 0.1 – 5.0 mL/min
Power Requirement ≤ 30 MPa
Dimension (L×W×H) 150 W
Net Weight 500×360×550 mm
Gross Weight 32 Kg
  • Flow rate range: with 0.001 to 9.999 mL/min

  • High pressure resistance

  • Modular design convenient to operate

  • Eluent pre-heating

  • Intelligent alarm function can detect leaks

  • Real-time detection of residual liquid in the eluent cartridge using an intelligent detector

  • The built-in gas-liquid separation system can filter out bubbles in the flow path, improving stability

  • Observatory intelligent work station

  • Intelligent switch to complete the startup parameter setting and shutdown operation

  • Accurate and reliable system

  • Run more samples and more molecules on a single system

  • Flexible processing with high productivity

  • High definition touch screen can display flow path and running status

  • Intelligent temperature control to ensure better accuracy of analysis

  • It is widely used in the fields of environment protection, disease control, food industries, chemical industries commercial labs, electronics, mining and metallurgy.