EziLab offers the Ion Chromatograph EZL-IC65, an ion chromatography system that separates anions or cations on an exchange column and measures them by conductivity, with on-line eluent generation removing manual eluent prep. A high-pressure pump reaches 42 MPa and delivers 0.001–9.999 mL/min, while the generator produces KOH or MSA eluent from 0.1 to 100 mM for isocratic or gradient runs. The ≤0.8 µL conductivity cell reads 0–50,000 µS/cm with 0.02 nS electronic noise, so trace ions and high-salt samples run on one platform. Eluent pre-heating steadies baselines, a built-in gas-liquid separator strips bubbles, and real-time cartridge level sensing warns before reagent runs out. An intelligent leak alarm, automatic start-up and shut-down, and an HD touchscreen showing the live flow path simplify unattended operation. Environmental agencies, disease control centers, food producers, electronics plants, mining companies and pharmaceutical labs use this ion chromatograph for routine ion quantification. Typical analyses include fluoride, chloride, nitrate and sulfate in drinking water, nitrite in cured meats, ultrapure rinse water checks, leach liquor profiling and counterion assays. Choose it over manual-eluent IC when gradient reproducibility and lower reagent handling matter. Compare other configurations under Ion Chromatographs, or go to the Ion Chromatograph page for its spec table.



Cell Volume ≤0.8 µL
Detection Range 0 to 50000 µS/cm
Detection Resolution ≤0.0020 ns/cm
Electronic Noise 0.02 ns
Pump Maximum Pressure 42 MPa
Pressure Display Accuracy ≤0.1 MPa
Flow Rate Range 0.001 to 9.999 mL/min
Detector Maximum Pressure 10.0 MPa
Eluent Type KOH/MSA
Eluent Concentration Range 0.1 to 100 mM
Gradient Accuracy 0.002
Pressure 0.1 – 5.0 mL/min
Power Requirement ≤ 30 MPa
Dimension (L×W×H) 150 W
Net Weight 500×360×550 mm
Gross Weight 32 Kg
  • Flow rate range: with 0.001 to 9.999 mL/min

  • High pressure resistance

  • Modular design convenient to operate

  • Eluent pre-heating

  • Intelligent alarm function can detect leaks

  • Real-time detection of residual liquid in the eluent cartridge using an intelligent detector

  • The built-in gas-liquid separation system can filter out bubbles in the flow path, improving stability

  • Observatory intelligent work station

  • Intelligent switch to complete the startup parameter setting and shutdown operation

  • Accurate and reliable system

  • Run more samples and more molecules on a single system

  • Flexible processing with high productivity

  • High definition touch screen can display flow path and running status

  • Intelligent temperature control to ensure better accuracy of analysis

•Measures fluoride, chloride, nitrate and sulfate in drinking water for environmental protection and disease control labs, using conductivity detection from 0 to 50,000 µS/cm.
•Checks nitrite in cured meats and other food samples, with online eluent generation that removes manual eluent preparation.
•Verifies ultrapure rinse water in electronics work, using a conductivity cell volume of 0.8 µL or less.
•Profiles leach liquors in mining and metallurgy, with a pump rated to 42 MPa and flow from 0.001 to 9.999 mL/min.
•Runs counterion assays in chemical industry labs, with KOH/MSA eluent from 0.1 to 100 mM, a leak alarm and a built-in gas-liquid separator.