High Speed Refrigerated Centrifuge EZL-HRC113 Catalog

Description

EziLab offers the High Speed Refrigerated Centrifuge EZL-HRC113, a floor standing plasma spinner that spins to 22,000 rpm and 41,495 g RCF with the chamber refrigerated between -20 and 40 °C. Nine fixed-angle rotors cover the table: a 24-place microtube head delivers the top 41,495 g at 20,000 rpm, a 12 by 5 mL head runs the full 22,000 rpm, and the largest carries six 250 mL bottles. Speed holds to ±10 rpm, the timer spans 1 to 99 minutes 59 seconds, programmable settings store routine methods, and noise stays at or under 60 dB(A). The exterior wipes clean after spills, and the footprint fits a lab corner. Research institutes, clinical laboratories, molecular biology groups, blood processing centers, enzyme producers and university core facilities use this high speed refrigerated centrifuge for cold, high-g separations across formats. Typical runs include plasma separation from whole blood, enzyme preservation during purification, molecular sample processing, lysate clearing, protein precipitation and cell harvesting in 250 mL bottles. Choose it over the single-rotor floor models when one machine must cover microtubes and bottles alike. A 4 °C setpoint describes the chamber, not the tube; at 20,000 rpm air friction warms the sample, so ask for a measured sample temperature after a full-speed run. Single-rotor rivals are judged in Laboratory Centrifuge and High Speed Refrigerated Centrifuge comparisons.

Specifications

Maximum Speed 22000rpm
Maximum RCF 41495 × g
Maximum Capacity 6 × 250 ml
Timer Range 1 to 99 min 59 s
Speed Accuracy ±10 r/min
Noise Level Less than equal to 60 dB(A)
Dimensions (W×D×H) 690 × 590 × 820 mm
Net Weight 240 kg

Features

Feature AreaDescription
Programmable SettingsRun settings can be stored as programs and recalled for repeat methods.
Chamber TemperatureChamber temperature control keeps cold-sensitive samples cooled during a spin.
Fixed-Angle RotorsA range of fixed-angle rotors covers small tubes up to large bottles.
Exterior SurfacesEasy-to-clean exterior surfaces wipe down quickly between users.
Floor-Standing CabinetA floor-standing cabinet houses the rotor and refrigeration unit, with a timer for run length.

Applications

  • Supports plasma separation from whole blood in blood processing centers and clinical labs.
  • Handles cold enzyme preparation for enzyme producers.
  • Suited to molecular sample processing for molecular biology groups.
  • Applied to lysate clearing and protein precipitate collection for research institutes.
  • Employed for cell harvesting in large bottles within core facilities.

Rotor Selection

Rotor Type Capacity (ml) Maximum Speed (r/min) Maximum RCF (×g) 
Fixed Angle Rotor 0112 × 5 ml22000r/min37877 × g
Fixed Angle Rotor 0224 × 1.5 ml20000r/min41495 × g
Fixed Angle Rotor 0316 × 10 ml18000r/min34835 × g
Fixed Angle Rotor 0412 × 15 ml17000r/min34835 × g
Fixed Angle Rotor 056 × 50 ml18000r/min34777 × g
Fixed Angle Rotor 068 × 50 ml16000r/min30395 × g
Fixed Angle Rotor 076 × 100 ml16000r/min30395 × g
Fixed Angle Rotor 084 × 250 ml13000r/min26039 × g
Fixed Angle Rotor 096 × 250 ml10000r/min8721 × g