EziLab offers the Mini Dry Bath Incubator EZL-MI101, a heating block that controls temperature from 5°C above room temperature up to 100°C, holding setpoint and uniformity within 0.5°C at 37°C with a 0.1°C display. It climbs from 37°C to 100°C within 15 minutes, and the timer runs from 1 to 999 hours, minutes, or seconds. Microprocessor control, auto-run, auto-resume after power loss, and built-in safety software fit a 135 by 100 by 75 mm body weighing 0.4 kg and drawing 24 W. Six interchangeable blocks accept 16 PCR tubes of 0.2 ml, 6 tubes of 0.5 ml, 5 tubes of 1.5 or 2.0 ml, 9.3 mm tubes, and 0.2 ml enzyme strips. Without water, this dry block heater avoids contamination, evaporation, and algae, so tubes stay clean through incubation and denaturation. Users heat DNA for denaturation, run enzyme digestions and ligations, and hold samples for reactions or short-term preservation. Molecular biology and biochemistry research labs run daily PCR prep and enzyme steps, while clinical labs incubate specimens before testing. Industrial QC teams heat reagents and samples, and teaching labs use this mini incubator for hands-on practical classes. Check your protocol for a heated lid requirement, because open tubes at 100°C lose volume to condensation on the caps and this listing mentions no lid, then compare the Laboratory Incubator category and Mini Dry Bath Incubator range.
| Temperature Setting Range | 0℃ to 100℃ |
|---|---|
| Temperature Control Range | Room temperature + 5℃ to 100℃ |
| Temperature Accuracy | ≤ ± 0.5℃ @ 37℃ |
| Temperature Uniformity | ≤ ± 0.5℃ @ 37℃ |
| Display Accuracy | 0.1℃ |
| Timing Range | 1 to 999 hours or 1 to 999 minutes or 1 to 999 seconds |
| Heating Time | ≤ 15 minutes (from 37℃ to 100℃) |
| Auto Running | Yes |
| Auto Resume to run | Yes |
| Power Consumption | 24 W |
| Dimension | 135 × 100 × 75 mm |
| Weight | 0.4 Kg |
| Feature Area | Description |
| Controller | Microprocessor control with a digital display. |
| Safety Software | Built-in safety software that watches the heating cycle. |
| Interchangeable Blocks | Swappable blocks for PCR tubes, microtubes and enzyme strips. |
| Waterless Heating | Dry block heating with no water bath to contaminate or evaporate. |
| Auto-Resume | Resumes a run after a power loss. |
0.2 ml × 16 PCR Tubes Block × 1 Piece 0.5 ml × 6 Centrifuge Tubes Block × 1 Piece 1.5 ml × 5 Centrifuge Tubes Block × 1 Piece 2.0 ml × 5 Centrifuge Tubes Block × 1 Piece 9.3 mm × 6 Block × 1 Piece 0.2 ml × 16 Enzyme Strip Block × 1 Piece