EziLab offers the Temperature Test Chamber EZL-TC157, a 22 L hot cold cycling chamber moving single parts between -40 °C and +150 °C on profiles stored in a 7 inch touchscreen. The 300 by 250 by 250 mm SUS304 workspace holds fluctuation to ±0.5 °C and uniformity within ±2.0 °C, an air-cooled compressor pulls it from +25 °C to -40 °C in 45 minutes or less, NiCr heaters lift it from +25 °C to +130 °C within 30 minutes, and steady airflow keeps the sample tracking. Data recording downloads over RS485, over-temperature protection cuts the heaters on a fault, a viewing window shows the part mid-cycle, and the cabinet measures 520 by 560 by 730 mm. Choose it over the 16 L unit when a module needs more cabling clearance. Electronics makers screen boards for solder fatigue in it, semiconductor labs cycle packages, telecom suppliers validate modules, and automotive plants run cold starts. Routine programs cover hot-cold cycling, dwell tests, and small part qualification. Powered modules need a cable port in the wall; ask whether one is fitted, and compare sizes through Climate Test Chamber and Temperature Test Chamber.
| Internal volume | 22 L |
|---|---|
| Temperature Range | - 40˚C to +150 ℃ |
| Temperature fluctuation | ≤ ± 0.5℃ |
| Temperature uniformity | ≤ ± 2.0℃ |
| Temperature deviation | ≤ 1.5℃ |
| Heating rate | +25℃ to +130℃ ≤ 30 minutes |
| Cooling rate | +25℃ to -40℃ ≤ 45 minutes |
| Inner chamber material | SUS304 stainless steel plate |
| Exterior Material | Reinforced Steel plate with electrostatic spraying |
| Insulation | Superfine fiberglass wool/polyurethane foam |
| Refrigeration mode | Refrigeration Compressors, air cooling |
| Controller | 7” Programmable touchscreen controller |
| Heating System | NiCr heater, independent system |
| Internal dimensions (D×W×H) | 300 × 250 × 250 mm |
| External dimensions (D×W×H) | 520 × 560 × 730 mm |
| Feature Area | Description |
|---|---|
| Chamber | Benchtop hot-cold cycling chamber with a stainless steel interior and a viewing window that shows the part mid-cycle. |
| Controller | Programmable touchscreen that stores test profiles and records data over long periods. |
| Cooling & Heating | Air-cooled compressor system paired with a separate heating system. |
| Airflow & Safety | Consistent air circulation around the sample and over-temperature protection that cuts the heaters on a fault. |
| Body & Data | Reinforced steel exterior with a spray finish and foam insulation, plus data download for stored results. |