Description
EziLab's Auto Chemistry Analyzer EZL-CA101 runs 200 tests per hour across 37 sample positions and 28 reagent positions, using 48 reusable cuvettes with a 6mm optical length and sample volumes from 2 to 70 microliters. Automatic cuvette washing, a refrigerated reagent tray with an independent switch, and real-time QC with multiple control options keep daily runs consistent, while bi-directional LIS connectivity over HL7 lets results flow straight into hospital and lab systems. Temperature control near 37C and an absorbance range of 0 to 3.0 Abs support liver function, kidney function, lipid profile, and glucose testing on one shared biochemistry analyzer platform. Clinical laboratories and hospital biochemistry units use this clinical chemistry analyzer for routine chemistry panels, while diagnostic centers rely on its throughput to handle walk-in and inpatient testing without backlogs during peak hours. Pharmaceutical QA facilities apply the same automated chemistry analyzer to stability and raw-material screening, and academic research programs use it for teaching automated biochemical methods alongside clinical studies. Hospital networks running centralized labs favor a blood chemistry analyzer of this throughput to consolidate testing from smaller satellite sites onto one instrument. See the Chemistry Analyzers and Auto Chemistry Analyzer pages for further specifications and ordering details.
Specifications
| Throughput | 200 tests/hour |
|---|---|
| Sample Volume | 2 to 70 µl |
| Reagent Volume | 20 to 350 µl |
| Sample Positions | 37 sample positions |
| Reagent Positions | 28 reagent positions |
| Absorbance | 0~3.0 Abs |
| Humidity | 30 to 80% |
| Washing | Automatic cuvettes washing |
| Probe Washing | Automatic washing interior and exterior |
| Reagent Cooling | Refrigerated tray with independent switch |
| Cuvettes | 48 reusable cuvettes, optical length 6mm |
| Mixed Probe | Independent stirring |
| Stat Function | Yes |
| Light Source | 6V/10W halogen lamp |
| Spectrophotometry | Post-spectral spectrophotometry |
| Calibration | Linear: K factor, 1-point, 2-point and multipoint linearNon-Linear: Spline, Polygon, Index, Logarithm, Logit-4P,Logit-5 |
| Quality Control | Real-time QC, Westward multi rule, Cumulative sum check, Twin Plot(2D) |
| Software | Windows 7/8/10, 32 or 64bit |
| LIS System | Bi-direction, support HL7 protocol |
| Interface | LAN port access |
| Printer | External, multiple reporting mode available |
| Temperature | 10 to 30°C |
| Temperature Control | 37±0.1°C, real time monitor |
| Water Consumption | Deionized water: 5 L/H |
| External Dimension (W×D×H) | 625×425×460 mm |
| Package Dimension (W×D×H) | 721×531×855 mm |
| Net Weight | 36 kg |
| Gross Weight | 55 kg |