Description
EziLab supplies the Digital Anemometer EZL-DA101 for cleanroom and industrial settings that need high resolution airflow sensing on a straightforward LCD display, without the min/max/average trending function found on other anemometers in this catalog. Covering 0-30 m/s, this LCD air velocity meter provides direct, high-resolution instantaneous readings, suited to spot checks and routine airflow verification where a single accurate reading at the moment of measurement is sufficient, rather than needing statistical tracking across a measurement period. That high-resolution sensing catches smaller airflow variations than a basic instrument would register, useful for verifying fume hood face velocity or general cleanroom and industrial airflow against a specification threshold, even without the trending data the min/max/average models capture. Industrial settings running quick, routine airflow spot checks — rather than extended cleanroom certification runs where tracking variability over time matters — get a simpler, more direct instrument here that still delivers the resolution needed for accurate pass/fail verification against a fixed threshold. Cleanroom and industrial facility teams needing fast, precise instantaneous airflow readings for routine verification work get that direct capability without the added complexity of trend-tracking functions they may not need for spot-check purposes. See the LCD Air Velocity Meter and Digital Anemometer ranges for high-resolution industrial airflow verification needs across USA cleanroom and industrial settings.
Specifications
| Wind Velocity Measurement Range | 0–30 m/s (0–5860 ft/min / 0–55 knots/ 0–65 Km/h/ 0–65 mph) |
|---|---|
| Wind Velocity Measurement Resolution | 0.001 (1.688/ 0.001/ 0.0036/ 0.002) |
| Wind Velocity Measurement Threshold | 0.3 (60/ 0.6/ 1/ 0.7) |
| Wind Velocity Measurement Accuracy | ±5% ±0.1 (±5% ±20/ ±5% ±0.2/ ±5% ±0.4/ ±5% ±0.2) |
| Wind Temperature Measurement Range | -10 to 45°C (14 to 113°F) |
| Wind Temperature Measurement Resolution | 0.1 |
| Wind Temperature Measurement Accuracy | ±2°C (±3.6°F) |
| Data Functions | Maximum / Minimum / Average / Current |
| Display | Digital LCD |
| Temperature Sensor | Negative Temperature Coefficient Resistance |
| Operating Temperature | -10 to 45°C |
| Operating Humidity | Less than 90% RH |
| Storage Temperature | -40 to 60°C |
| Dimensions (L × D × H) | 165 × 85 × 39 mm |
| Weight | 0.18 Kg |
Features
Standard Accessories
Name | Quantity |
USB Cable | 1 Piece |
Applications