EziLab offers the Visible Spectrophotometer EZL-VS101, a single beam spectrophotometer that covers 325 to 1000 nm with a 2 nm spectral bandwidth and 0.1 nm wavelength resolution. Wavelength error stays within ±2 nm with ≤0.5 nm repeatability, and photometric error stays within ±0.5 %T. A tungsten lamp, 1200 lines/mm grating, and silicon photodiode detector give stability of ≤0.002 A per 30 minutes at 500 nm and stray light of ≤0.1 %T at 360 nm. Users read results in transmittance, absorbance, concentration, or factor mode on a 128 × 64 dot LCD, and wavelength sets automatically. Standard curves build quickly, and USB and parallel ports send data to a PC or printer. Four 1 cm glass cuvettes, a black block, and a dust cover come standard. As a benchtop spectrophotometer, it measures color, dye concentration, and colorimetric assay results without paying for unneeded UV range. Clinical diagnostics and medical laboratories run blood chemistry and enzyme assays, while environmental testing labs check water for nitrate, phosphate, and other analytes. Pharmaceutical labs perform content and dissolution checks, and food and beverage QC teams measure color, clarity, and additive levels in finished products. See the Visible Spectrophotometers and Visible Spectrophotometer pages for full specifications.
| Wavelength Range | 325 to 1000 nm |
|---|---|
| Spectral Bandwidth | 2 nm |
| Wavelength Accuracy | ± 2 nm |
| Wavelength Repeatability | Less than or equal to 0.5 nm |
| Wavelength Setting | Automatic |
| Wavelength Resolution | 0.1 nm |
| Photometric Range | - 0.3 to 3 (Absorbance), 0 to 200 % (Transmittance), 0 to 9999 (Concentration) |
| Photometric Accuracy | ± 0.5 % T |
| Photometric Repeatability | Less than or equal to 0.2 % T |
| Photometric Mode | T, A, C, F |
| Detector | Silicon Photodiode |
| Stability | Less than or equal to 0.002 A / 30 min at 500 nm |
| Stray Light | Less than or equal to 0.1 % T at 360 nm |
| Optical System | Single beam, grating 1200 lines /mm |
| Light Source | Tungsten Lamp |
| Display | 128 × 64 Dots LCD |
| Output | USB Port & Parallel Port |
| Power Requirements | AC 85 ~ 250 |
| Feature Area | Description |
| Wavelength Setting | Automatic wavelength setting moves to the chosen wavelength without manual dialing. |
| Light Source | Tungsten lamp light source for visible range work. |
| Standard Curve | Rapid standard curve setup for concentration measurements. |
| Measurement Modes | Transmittance, absorbance, concentration and factor modes on one panel. |
| Data Output | USB and parallel ports for sending results out of the instrument. |
| Spectrophotometer | 1 unit |
| 1cm Glass Cuvette | 4 pieces |
| Power Cord | 1 piece |
| User’s Manual | 1 piece |
| Black Block | 1 piece |
| Dust Cover | 1 piece |
| 1 | Cell Holders |
| 2 | Control Units |
| 3 | Lamps |
| 4 | Glass Cuvette With Lid |
| 5 | Quartz Cuvette With Lid |
| 6 | Micro Cuvette |
| 7 | PC Software |
The Visible Spectrophotometer EZL-VS101 offers a wavelength range of either 325 to 1000 nm or 190 to 1000 nm, depending on the selected model configuration. This broad range covers the entire visible spectrum and extends into both the near-infrared and ultraviolet regions. Such flexibility is essential for a wide range of applications, including biochemical assays, pharmaceutical analyses, and environmental monitoring. The extended range enables detection of compounds with varied absorption properties, making it suitable for analyzing both organic and inorganic substances in liquid and solid form.
Ezilab’s Visible Spectrophotometer EZL-VS101 ensures high-performance accuracy through its grating monochromator, which delivers a wavelength accuracy of ±2 nm and repeatability of ?0.5 nm. Its photometric accuracy of ±0.5%T ensures dependable quantification of sample concentration. Furthermore, stray light is controlled to ?0.1%T, reducing signal interference and improving sensitivity. The system's stability within ?0.002 A / 30 min helps maintain result consistency during extended runs, essential for kinetic studies, standard curve calibration, and comparative multi-sample testing.
Our Visible Spectrophotometer EZL-VS101 supports multiple measurement modes: Transmittance (T), Absorbance (A), Concentration (C), and Factor (F). This makes it highly versatile for various applications, from basic concentration determination to quantitative assays and kinetic monitoring. It can be used for standard curve creation, chemical purity evaluation, or unknown sample analysis. These capabilities make it a valuable tool in educational institutions, clinical diagnostics, environmental testing labs, and industrial quality control departments, where different testing protocols are routinely followed.
Ezilab’s Visible Spectrophotometer EZL-VS101 is designed for ease of use, featuring a 128 × 64 dot LCD for clear data visualization, a responsive keypad, and automatic wavelength setting to simplify operation. It allows quick calibration, standard curve setup, and intuitive navigation through measurement modes. The inclusion of USB and parallel ports for data transfer further streamlines the workflow. Its straightforward operation makes it ideal for first-time users, students, and professionals alike, reducing training time and enhancing lab productivity.
The Visible Spectrophotometer EZL-VS101 is equipped with both USB and parallel port outputs, providing seamless connectivity to printers and computers for data export. This facilitates easy storage, retrieval, and documentation of test results, which is essential for regulatory reporting, quality assurance, and research archiving. Its compatibility with standard lab software improves workflow integration, allowing for real-time data sharing, automated backups, and enhanced traceability. These features are especially beneficial in multi-user lab environments or setups requiring network-based data access.
Our Visible Spectrophotometer EZL-VS101 is built with a robust and compact design, making it highly durable for long-term laboratory use. It requires minimal maintenance, with easy-to-clean surfaces and a dust-resistant optical compartment that helps maintain accuracy over time. The lamp and optical components are accessible for replacement or servicing, ensuring low downtime. In addition, the system features self-check diagnostics and internal calibration functions, reducing the need for frequent manual adjustments. Its reliability and low upkeep make it ideal for busy, high-throughput labs.