Chromatographs


Ezilab offers Chromatographs for chemical analysis laboratories, pharmaceutical companies, environmental agencies, petrochemical testing units, food analysis organizations, forensic departments, and academic research centers requiring structured separation workflows. The Chromatographs range covers ion chromatographs, gas chromatographs, liquid chromatographs, and GC-MS systems supporting compound detection, quantification, and separation across diverse matrices under FDA 21 CFR Part 11, EPA Method 300, USP chromatographic method requirements, and ASTM standards. Ion chromatographs support anion and cation analysis in water and environmental samples, while gas and liquid chromatographs handle volatile compounds and complex mixtures in pharmaceutical and forensic testing. Each chromatograph category covers diverse pressure ratings, detector configurations, and eluent systems. Quality standards support validated performance and global analytical standard alignment across all chromatograph categories. EziLab's Chromatographs and Analytical HPLC Systems address separation needs across USA pharmaceutical and environmental laboratory settings.
  • Pump Flow Rate: 0,001 to 10.000 mL/min (Step: 0.001 mL/min)
  • Pump Accuracy: ≤ +0.3%
  • Pump Precision: ≤ 0.1% RSD
  • Maximum Pressure: 42 MPa (6000 psi)
  • Flow Rate Setting Range: 0.0000 to 12.0000mL/min
  • Flow Rate Setting Increment: 0.0001mL/min
  • Gradient Error: Less than equal to 0.75%
  • Gradient Stability: 0.2% RSD (5% to 95%, 0.2 to 2.0mL/min)
  • Retention time repeatability: Less than 0.008%
  • Peak area repeatability: Less than 0.5%
  • Injection ports supported: 2
  • Detectors supported: 4
  • Oven Inside capacity: 22L
  • Oven Temperature Range: RT up 5°C to 400°C
  • Oven Temperature Accuracy: ±0.1°C
  • Oven Temperature Programming: 9 steps
  • Gas Chromatography Flow Rate: 1 to 1.5 ml/min
  • Maximum Flow Rate: 10 ml/min
  • Inlet Temperature: 450 °C
  • Pressure Range: 0 to 100 psi
  • Ionization Energy: 0–240 eV
  • Ion Source: Electron Ionization (EI)
  • Emission Current: 0–350 μA
  • Filament: Dual filament (EI source equipped)
  • Retention time repeatability: < 0.008%
  • Peak area repeatability: < 0.5%
  • Display: 8-inch high-resolution capacitive touchscreen
  • User interface: Android-based graphical interface with self-diagnosis & leakage detection
  • Cell Volume: ≤0.8 µL
  • Detection Range: 0 to 45000 µS/cm
  • Detection Resolution: ≤0.0020 ns/cm
  • Electronic Noise: 0.02 ns
  • Cell Volume: ≤0.8 µL
  • Detection Range: 0 to 45000 µS/cm
  • Detection Resolution: ≤0.0020 ns/cm
  • Electronic Noise: 0.02 ns
  • Cell Volume: ≤0.8 µL
  • Detection Range: 0 to 50000 µS/cm
  • Detection Resolution: ≤0.0020 ns/cm
  • Electronic Noise: 0.02 ns
  • Cell Volume: ≤0.8 µL
  • Detection Range: 0 to 50000 µS/cm
  • Detection Resolution: ≤0.0020 ns/cm
  • Electronic Noise: 0.02 ns
  • Cell Volume: ≤0.8 µL
  • Detection Range: 0 to 50000 µS/cm
  • Detection Resolution: ≤0.0020 ns/cm
  • Temperature Range: 5° to 60°C