Description
EziLab offers the Flame Photometer EZL-FP142, a 4-channel digital flame photometer that measures potassium, sodium, lithium, and calcium in one workflow. Choose it over the 3-channel clinical model when calcium matters, as agricultural labs require it for soil fertility and plant tissue analysis. Test ranges cover K from 0.15 to 100 ppm, Na from 0.18 to 100 ppm, Li from 0.1 to 30 ppm, and Ca from 0.1 to 1000 ppm, with detection limits of ≤0.156 ppm K, ≤0.184 ppm Na, ≤0.1035 ppm Li, and ≤2 ppm Ca. Reproducibility stays within 2%, readings arrive in 8 seconds, and the system draws 3 mL of sample per minute. An LPG flame, included air compressor, and pressure-reducing valve make setup complete out of the box. Safety alarms detect gas leakage, trigger automatic flameout protection, and shut off gas automatically. A touch-screen display with push-button ignition, multilingual interface, data storage, USB output, and built-in thermal printer support traceable reporting. Clinical laboratories monitor serum electrolytes and lithium therapy levels, agricultural labs test soil fertility and plant nutrient content, and food and beverage producers check mineral content for quality control and nutrition labeling. Calcium reads up to 1000 ppm while potassium and sodium stop at 100 ppm, so estimate how many of your samples need dilution before comparing the Spectrophotometer category and Flame Photometer range.
Specifications
| Testing Elements | K, Na, Li, Ca |
|---|---|
| Channels | 4 |
| Test Range |
K:0.15 to 100 ppm Na: 0.18 to 100 ppm Li: 0.1 to 30 ppm Ca: 0.1 to 1000 ppm Li: 0.1 to 30 ppm |
| LOD |
K: Less than or equal to 0.156 ppm Na: Less than or equal to 0.184ppm Ca : Less than or equal to 2ppm Li: Less than or equal to 0.1035ppm |
| Linearity Error |
K: less than or equal to 0.195 ppm Na: less than or equal to 0.69 ppm Li: less than or equal to 0.1499 ppm Ca: less than or equal to 3ppm |
| Response Time | 8 s |
| Sample Uptake | 3ml/min |
| Stability | less than or equal to 3% drift within 15 s, less than equal to 15 % drift within 16 minutes |
| Reproducibility | less than or equal to 2% |
| Printer | Optional built in thermal printer |
| COM | USB |
| Fuel | LPG |
| Power | AC 220V/50Hz or AC 110V/60Hz |
| Package | 570 × 530 × 400 mm |
| Net Weight | 18Kg |
Features
| Feature Area | Description |
| Elements | Concentration measurement for potassium, sodium, lithium, and calcium. |
| Interface | Multilingual touch-screen interface. |
| Ignition | Push-button ignition. |
| Gas Safety | Gas leak alarm, automatic flameout protection, and automatic gas shut-off. |
| Data and Output | Data storage with USB output and an optional built-in thermal printer. |
Standard Accessories
Standard Accessories:
LPG Reducing Valve | 1 piece |
Stainless steel bellows for LPG | 1 piece |
Silica gel tubing for waste liquid | 1 piece |
PU tubing for air | 1 piece |
Air Compressor | 1 piece |
Optional Accessories
1. | Built in thermal Printer |
2. | Software |
Applications