Spectrophotometers

Ezilab Spectrophotometers have a durable design that maintains high-performance standards under operational changes. Their full-scan analysis enables spectral analysis across a broad range of wavelengths. The fixed path length ensures consistent optical path for accurate measurements. They have spectral bandwidths ranging from 0.5nm to 4 nm, allowing finer resolution for reliable results. Our Spectrophotometers have durable and stable light sources for consistent measurements over time.

  • Ions Measured: K, Na, Li, Ca, Ba
  • Element Detection Limit: 2 elements
  • Measurement Range: K: 0 – 100 ppm
    Na: 0 – 100 ppm
    Li: 0 – 100 ppm
    Ca: 0 – 1000 ppm
    Ba: 0 – 1000 ppm
  • Stability: 15s ≤ 3%
  • Ions Measured: K, Na, Li, Ca, Ba
  • Element Detection Limit: 3 elements
  • Measurement Range: K: 0 – 100 ppm
    Na: 0 – 100 ppm
    Li: 0 – 100 ppm
    Ca: 0 – 1000 ppm
    Ba: 0 – 1000 ppm
  • Stability: 15s ≤ 3%
  • Ions Measured: K, Na, Li, Ca, Ba
  • Element Detection Limit: 4 elements
  • Measurement Range: K: 0 – 100 ppm
    Na: 0 – 100 ppm
    Li: 0 – 100 ppm
    Ca: 0 – 1000 ppm
    Ba: 0 – 1000 ppm
  • Stability: 15s ≤ 3%
  • Ions Measured: K, Na, Li, Ca, Ba
  • Element Detection Limit: 5 elements
  • Measurement Range: K: 0 – 100 ppm
    Na: 0 – 100 ppm
    Li: 0 – 100 ppm
    Ca: 0 – 1000 ppm
    Ba: 0 – 1000 ppm
  • Stability: 15s ≤ 3%
  • Wavelength Range: 200 nm – 800 nm
  • Wavelength Accuracy: 1 nm
  • Spectral Resolution: ≤3 nm (FWHM at Hg546 mm)
  • Minimum Sample Size: 0.5 - 2µl
  • Wavelength Range: 200 nm – 800 nm
  • Wavelength Accuracy: 1 nm
  • Spectral Resolution: ≤3 nm (FWHM at Hg546 mm)
  • Minimum Sample Size: 0.5 - 2µl
  • Wavelength Range: 260 nm, 280 nm
  • Minimum Sample Size: 1 - 2µl
  • Path Length: 0.5 mm
  • Absorbance Precision: 0.005Abs
  • Wavelength Range: 200 nm – 800 nm
  • Wavelength Accuracy: 1 nm
  • Spectral Resolution: ≤3 nm (FWHM at Hg546 mm)
  • Minimum Sample Size: 0.5 - 2µl
  • Wavelength Range: 190 nm – 1100 nm
  • Spectral Bandwidth: 0.5/1/2/4/5 nm
  • Optical System: Single beam
  • Wavelength Accuracy: ±0.3 nm
  • Wavelength Range: 190 nm – 1100 nm
  • Spectral Bandwidth: 1 nm
  • Optical System: Single beam
  • Wavelength Accuracy: ±0.3 nm
  • Wavelength Range: 190 nm – 1100 nm
  • Spectral Bandwidth: 1.8 nm
  • Optical System: Single beam
  • Wavelength Accuracy: ±0.3 nm
  • Wavelength Range: 190 nm – 1100 nm
  • Spectral Bandwidth: 1.8 nm
  • Optical System: Single beam (1200 lines/mm grating)
  • Wavelength Accuracy: ±0.5 nm
  • Wavelength Range: 190 nm – 1100 nm
  • Spectral Bandwidth: 2 nm
  • Optical System: Single beam (1200 lines/mm grating)
  • Wavelength Accuracy: ±0.5 nm
  • Wavelength Range: 320 nm – 1100 nm
  • Spectral Bandwidth: 2 nm
  • Optical System: Single beam (1200 lines/mm grating)
  • Wavelength Accuracy: ±0.5 nm
  • Wavelength Range: 190 nm – 1100 nm
  • Spectral Bandwidth: 2 nm
  • Optical System: Single beam (1200 lines/mm grating)
  • Wavelength Accuracy: ±0.5 nm
  • Wavelength Range: 200 nm – 1000 nm
  • Spectral Bandwidth: 4 nm
  • Optical System: Single beam (1200 lines/mm grating)
  • Wavelength Accuracy: ±0.5 nm
  • Wavelength Range: 320 nm – 1100 nm
  • Spectral Bandwidth: 4 nm
  • Optical System: Single beam (1200 lines/mm grating)
  • Wavelength Accuracy: ±1 nm
  • Wavelength Range: 190 nm – 1100 nm
  • Spectral Bandwidth: 0.5/1.0/2.0/4.0/5.0 nm
  • Optical System: Double beam
  • Wavelength Accuracy: ±0.3 nm
  • Wavelength Range: 190 nm – 1100 nm
  • Spectral Bandwidth: 1 nm
  • Optical System: Double beam
  • Wavelength Accuracy: ±0.3 nm
  • Wavelength Range: 190 nm – 1100 nm
  • Spectral Bandwidth: 1.8 nm
  • Optical System: Double beam
  • Wavelength Accuracy: ±0.3 nm
  • Wavelength Range: 190 nm – 1100 nm
  • Spectral Bandwidth: 2 nm
  • Optical System: Single beam
  • Wavelength Accuracy: ±0.5 nm
  • Wavelength Range: 190 nm – 1100 nm
  • Spectral Bandwidth: 2 nm
  • Optical System: Double beam
  • Wavelength Accuracy: ±0.5 nm
  • Wavelength Range: 325 nm to 1000 nm
  • Spectral Bandwidth: 4 nm
  • Optical System: Single Beam (1200 lines/mm grating)
  • Wavelength Accuracy: ±2 nm
  • Wavelength Range: 325nm to 1000nm
  • Spectral Bandwidth: 2 nm
  • Optical System: Single Beam (Holographic blazed 1200 lines/mm grating monochromator)
  • Wavelength Accuracy: ±2 nm