Description
EziLab offers the Gas Chromatography Mass Spectrometry EZL-GCMS101, a single quadrupole GCMS machine that separates volatile and semi-volatile compounds by gas chromatography, then identifies them by mass. A dual-filament electron ionization source runs at 0–240 eV, feeding an all-metal quadrupole with pre-quadrupole that covers 1.5–1200 u at unit mass separation. Scan speed reaches 20,000 u/s, the dynamic range spans 10⁷, and mass axis drift stays under 0.10 u over 48 hours. Sensitivity achieves a 1,500:1 signal-to-noise ratio for 1 pg/µL OFN. An ultra-inert flow path limits analyte loss, a 250 L/s turbomolecular pump with quick-lock venting shortens restart time, and SCAN, SIM or combined acquisition suits screening and targeted quantitation. MassExpert software adds one-touch autotune, batch processing, NIST library matching with deconvolution and report templates. Forensic labs, hospitals, environmental agencies, food testers, petrochemical refiners and polymer producers use this quadrupole GC-MS for compound identification. Uses include illicit drug and toxicology screening, pesticide and VOC monitoring, flavor and contaminant profiling, fuel hydrocarbon analysis and additive characterization. Choose it over GC-FID when unknown peaks need structural confirmation, not just retention times. Review the GC MS category for related systems, and visit the Gas Chromatography Mass Spectrometry page for the full specification sheet.
Specifications
| Ionization Energy | 0–240 eV |
|---|---|
| Ion Source | Electron Ionization (EI) |
| Emission Current | 0–350 μA |
| Filament | Dual filament (EI source equipped) |
| Interface Temperature | Up to 400 °C |
| Ion Source Temperature | Up to 350 °C |
| Mass Filter | All-metal quadrupole with pre-quadrupole |
| Mass Range | 1.5 – 1200 u |
| Mass Resolution | Unit |
| Mass Axis Stability | Better than 0.10 u / 48 hours |
| Dynamic Range | 10⁷ |
| Scan Rate | Up to 20,000 u/s |
| SIM Channels | 64 ions × 128 groups |
| Vacuum System | Turbomolecular pump (250 L/s) with mechanical oil pump (4 m³/h) or dry pump (10.8 m³/h) |
| Vacuum Lock | Quick-lock function for faster secondary startup |
| Signal-to-Noise Ratio | 1,500:1 (m/z 272, 1 pg/µL OFN, EI mode) |
| Flow Path | Ultra-inert (inlets, liners, columns, fittings, ion source) |
| Software | MassExpert acquisition & analysis software, one-touch autotune, batch processing, trend charts |
| Spectral Library | NIST library, integrated deconvolution & spectrum matching |
| Reporting | Built-in smart report templates |
| Scanning Modes | SCAN, SIM, SCAN/SIM |
| Acoustic Emission | < 70 dB |
| Operating Environment | 15–35 °C, RH 20–80% (non-condensing) |
| Storage Environment | -40–70 °C, RH 0–95% (non-condensing) |