EziLab offers the Gas Chromatography Mass Spectrometry EZL-GCMS101, a GC-MS system built around an all-metal quadrupole and a dual-filament electron ionization source. It covers 1.5 to 1200 u at unit mass separation, scans up to 20,000 u/s, and holds mass axis drift below 0.10 u over 48 hours with a 10⁷ dynamic range. A 250 L/s turbomolecular pump with quick-lock restart, an ultra-inert flow path, and a 1,500:1 signal-to-noise ratio round out the hardware. SCAN, SIM, and combined SCAN/SIM modes, with SIM tables of 64 ions across 128 groups, let this GC-MS instrument screen unknowns and quantify trace targets in the same run. MassExpert software adds one-touch autotune, batch processing, and trend charts, while NIST library matching with deconvolution speeds compound identification. Built-in report templates turn results into finished reports quickly. Environmental testing labs measure pesticides, VOCs, and semivolatile pollutants, while food and beverage centers screen residues and flavor compounds. Forensic and toxicology units identify drugs and poisons, clinical diagnostic labs analyze metabolites, and pharmaceutical QC teams check impurities and residual solvents. Academic chemistry programs and materials researchers use this quadrupole GC-MS for teaching and routine characterization work. Between SCAN for unknowns and SIM for trace targets, the split in your workload is the first thing to settle before comparing the Chromatograph category and GC MS range.
| Ionization Energy | 0–240 eV |
|---|---|
| Ion Source | Electron Ionization (EI) |
| Emission Current | 0–350 μA |
| Filament | Dual filament (EI source equipped) |
| Interface Temperature | Up to 400 °C |
| Ion Source Temperature | Up to 350 °C |
| Mass Filter | All-metal quadrupole with pre-quadrupole |
| Mass Range | 1.5 – 1200 u |
| Mass Resolution | Unit |
| Mass Axis Stability | Better than 0.10 u / 48 hours |
| Dynamic Range | 10⁷ |
| Scan Rate | Up to 20,000 u/s |
| SIM Channels | 64 ions × 128 groups |
| Vacuum System | Turbomolecular pump (250 L/s) with mechanical oil pump (4 m³/h) or dry pump (10.8 m³/h) |
| Vacuum Lock | Quick-lock function for faster secondary startup |
| Signal-to-Noise Ratio | 1,500:1 (m/z 272, 1 pg/µL OFN, EI mode) |
| Flow Path | Ultra-inert (inlets, liners, columns, fittings, ion source) |
| Software | MassExpert acquisition & analysis software, one-touch autotune, batch processing, trend charts |
| Spectral Library | NIST library, integrated deconvolution & spectrum matching |
| Reporting | Built-in smart report templates |
| Scanning Modes | SCAN, SIM, SCAN/SIM |
| Acoustic Emission | < 70 dB |
| Operating Environment | 15–35 °C, RH 20–80% (non-condensing) |
| Storage Environment | -40–70 °C, RH 0–95% (non-condensing) |
| Feature Area | Description |
| Ion Source | Electron ionization source with dual filament and 0 to 240 eV energy. |
| Mass Filter | All-metal quadrupole with pre-quadrupole covering 1.5 to 1200 u. |
| Scan Modes | SCAN, SIM and SCAN/SIM at up to 20,000 u/s, with SIM of 64 ions × 128 groups. |
| Vacuum System | 250 L/s turbomolecular pump with oil or dry backing pump. |
| Software | MassExpert with one-touch autotune and NIST library matching with deconvolution. |