Description
EziLab supplies the Hematology Analyzer EZL-HA101 with impedance-based cell counting and a cyanide-free HGB method across 21 parameters, including WBC, RBC, HGB, HCT, and platelet indices. Throughput reaches 60 tests per hour from a 10-microliter normal sample or 20-microliter pre-diluted sample, with three histograms covering WBC, RBC, and PLT distributions. Venous, capillary, and pre-diluted counting modes cover different sample types, an 8-inch touchscreen handles data entry, and a built-in thermal printer or external USB printer outputs results, with RS232, USB, VGA, and LIS connectivity for lab networks. Storage holds up to 100,000 results with histogram data, backed by manual or automatic calibration checks. Clinical laboratories and hospital diagnostic centers run the analyzer for routine complete blood count and differential cell counting across walk-in and inpatient sample volumes, while blood banks apply the same impedance method to donor screening panels. Reference laboratories and academic research programs use the three counting modes to process venous, capillary, and pre-diluted samples without switching instruments. The 27kg gross weight and compact 580x470x590mm package suit smaller diagnostic centers and satellite labs with limited bench space, and the on-board reagent pack cuts manual handling between batches. See the Hematology Analyzers and Hematology Analyzer pages for related models.
Specifications
| Sample Volume | Normal: 10µl, 20µl (pre-diluted blood) |
|---|---|
| Throughput | 60 tests/hour |
| Storage | 1,00,000 results with histogram |
| Histograms | 3 histograms (including WBC, RBC, PLT) |
| Aperture Diameter | WBC Chamber: 100µm; RBC/PLT Chamber: 70µm |
| Measuring Principle | Impedance for cell counting Cyanide free method for HGB |
| Parameters | WBC, NEU#, LYM#, MID#, NEU%, LYM%, MID%, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-SD, RDW-CV, PLT, MPV, PDW, PCT, P-LCR |
| Calibration | Manual and auto calibration |
| Counting Modes | Venous, Capillary, Pre-diluted |
| Printer | Built-in thermal printer, USB to external printer |
| Data Input | 8 inch touch screen, keyboard, mouse |
| Output | RS232 port, USB port, VGA port, LIS system available |
| Parameter (CV) | 21 parameters (including WBC, Mid%, Lym%, Gran%, Mid%, Lym%, Gran%, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-SD, RDW-CV, PLT, MPV, PDW, PCT, LCR, P-LCC) |
| Background Parameter | WBC ≤ 0.3× 10⁹/L, RBC ≤ 0.03 × 10¹²/L, HGB ≤ 1g/L, HCT ≤ 5.0%, PLT≤ 10×10⁹ /L |
| Package Size (W×D×H) | 580×470×590 mm |
| Reagent Package Size (W×D×H) | 450×410×310 mm |
| Gross Weight | 27 kg |
Features
Applications