EziLab offers the Hematology Analyzer EZL-HA101, a compact hematology analyzer that counts cells by impedance and measures HGB by a cyanide-free method, running 60 tests per hour from 10 µL of normal sample or 20 µL of pre-diluted blood. It reports WBC, RBC, HGB, HCT, and platelet indices with three histograms for WBC, RBC, and PLT, and venous, capillary, and pre-diluted modes cover different sample types. An 8-inch touchscreen handles entry, a built-in thermal printer or USB external printer outputs results, RS232, USB, VGA, and LIS connect the lab network, and memory holds 100,000 results with histogram data. Manual and automatic calibration apply, an on-board reagent pack limits handling, and the package measures 580 by 470 by 590 mm at 27 kg gross. Choose it over the laser-scatter siblings when impedance counting at 60 tests per hour covers the routine blood count. Clinical laboratories and hospital diagnostic centers need same-day counts from small samples, blood banks want donor screening, and satellite labs with limited bench space need a small footprint. Typical uses include routine complete blood count, differential cell counting, donor screening panels, and micro-sample testing. Which counting method fits your routine? The Analyzer and Hematology Analyzer pages compare them.



Quantity:
$3825
Sample Volume Normal: 10µl, 20µl (pre-diluted blood)
Throughput 60 tests/hour
Storage 1,00,000 results with histogram
Histograms 3 histograms (including WBC, RBC, PLT)
Aperture Diameter WBC Chamber: 100µm; RBC/PLT Chamber: 70µm
Measuring Principle Impedance for cell counting Cyanide free method for HGB
Parameters WBC, NEU#, LYM#, MID#, NEU%, LYM%, MID%, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-SD, RDW-CV, PLT, MPV, PDW, PCT, P-LCR
Calibration Manual and auto calibration
Counting Modes Venous, Capillary, Pre-diluted
Printer Built-in thermal printer, USB to external printer
Data Input 8 inch touch screen, keyboard, mouse
Output RS232 port, USB port, VGA port, LIS system available
Parameter (CV) 21 parameters (including WBC, Mid%, Lym%, Gran%, Mid%, Lym%, Gran%, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-SD, RDW-CV, PLT, MPV, PDW, PCT, LCR, P-LCC)
Background Parameter WBC ≤ 0.3× 10⁹/L, RBC ≤ 0.03 × 10¹²/L, HGB ≤ 1g/L, HCT ≤ 5.0%, PLT≤ 10×10⁹ /L
Package Size (W×D×H) 580×470×590 mm
Reagent Package Size (W×D×H) 450×410×310 mm
Gross Weight 27 kg
Feature AreaDescription
DetectionImpedance cell counting, cyanide-free HGB method
Throughput60 tests per hour, 10 µL sample volume
Sample ModesVenous, capillary, pre-diluted
Display8-inch touchscreen, keyboard and mouse input
Storage and Output100,000 results with histograms, built-in thermal printer
  • Applied by clinics for fast capillary counts from a 10 µL sample.
  • Employed by space-limited satellite labs for NEU, LYM and MID differential counting.
  • Suited to hospital and routine labs for CBC runs at 60 tests/hour with three histograms.
  • Supports blood banks with donor screening panels through impedance counting and cyanide-free HGB.
  • Handles micro-sample testing in pre-diluted mode using 20 µL of diluted blood.
  • Fits connected workflows that need RS232, USB, VGA and LIS output with 100,000 stored results.