Description
EziLab offers the Analytical HPLC System EZL-AHS52, a modular liquid chromatograph built for high-pressure separation with UV-Visible detection and optional fluorescence, refractive index, and electrochemical detectors. The pump reaches up to 75 MPa with a flow range of 0.0000 to 12.0000 mL/min in 0.0001 mL/min steps, holding ±0.20% flow accuracy, ≤0.075% RSD flow stability, and ≤0.75% gradient error. A 108-position autosampler (2 × 54 vials, 2 mL) also accepts 96-well plates, delivering ≤0.3% RSD injection repeatability, ≤0.002% cross contamination, and optional cooling from 4 to 40°C. The column oven controls temperature from 4 to 90°C with ±0.03°C/h stability, and the system ships with a column oven, three columns, and a solvent organiser. Flow-to-needle injection, optimized needle cleaning, and automated injection control support unattended batch runs across full shifts, freeing analysts for other tasks. In industrial settings, pharmaceutical laboratories use this HPLC machine for compound separation, impurity profiling, and method validation, while biotechnology and chemical companies run routine purity testing and component identification. Food safety centers and environmental monitoring agencies detect trace compounds in complex sample mixtures, and academic institutions rely on it for quantitative and qualitative research. See the Liquid Chromatographs and Analytical HPLC System EZL-AHS52 pages for full specifications.
Specifications
| Flow Rate Setting Range | 0.0000 to 12.0000mL/min |
|---|---|
| Flow Rate Setting Increment | 0.0001mL/min |
| Gradient Error | Less than equal to 0.75% |
| Gradient Stability | 0.2% RSD (5% to 95%, 0.2 to 2.0mL/min) |
| Flow Rate Setting Value Error | ± 0.20% |
| Flow Rate Stability | Less than equal to 0.075% RSD |
| Maximum Operating Pressure | 62MPa /75MPa |
| Autosampler Linearity | R ≥ 0.9999 (1.0μL to 50μL) |
| Autosampler Cross Contamination | Less than equal to 0.002% |
| Number Of Injection Bits | 108 bits (2 ×54, 2mLsample bottle) |
| Injection Mode | flow to needle |
| Injection Volume | 100μL, 200μL, 500μL, 1000μL, 1500μL, 2000 μL |
| Repeatability |
Less than 0.3 % RSD (2μL to Max) Less than 1.0 % RSD (0.1μL to 1.9μL) |
| Linear Correlation Coefficient | Greater than 0.9999 |
| Number of Sample Position | 108 (2×54, 2mL), 96-well plates |
| Temperature Setting Range | 4 to 40 ℃ (optional refrigeration) |
| Temperature Setting Value Error | ±0.5℃ (optional refrigeration) |
| Temperature Stability | ±0.5℃ (optional refrigeration) |
| Column Oven Temperature Range | 4℃ to 90℃ |
| Column Oven Temperature Stability | ± 0.03℃/h |
| Column Oven Temperature Setting Value Error | ± 0.1℃ |
| Autosampler Dimension | 930 × 520 × 570 mm |
| Column Oven Dimension | 690 × 520 × 550 mm |
| Pump & Detector Dimension | 830 × 520 × 430 mm |
| Fluorescence Detector Dimension | 640 × 480 × 400 mm |
| Refractive Index Detector Dimension | 640 × 470 × 400 mm |
| Electrochemical Detector Dimension | 610 × 520 × 370 mm |
| Autosampler Weight | 51 Kg |
| Column Oven Weight | 32 Kg |
| Pump & Detector Weight | 32.2 Kg |
| Fluorescence Detector Weight | 37.5Kg |
| Refractive Index Detector Weight | 29.5 Kg |
| Electrochemical Detector Weight | 28.5 Kg |
| Total Weight | 232 Kg |
Features
Standard Accessories
Optional Accessories
Applications