Description
EziLab auto chemistry analyzer EZL-CA104 delivers 600 tests/hour with 120 reusable cuvettes and post-spectral spectrophotometry for automated biochemical analysis of serum, plasma, urine, and body fluids. The chemistry machine for laboratory use supports 90 sample positions and 180 refrigerated reagent positions with independent switch cooling for controlled assay conditions across high-volume diagnostic workloads. Eight-wavelength photometry (340–700nm) with automatic cuvette and probe washing — interior and exterior — maintains cycle integrity and measurement consistency. Multi-point calibration with real-time QC, Westgard multi-rule, cumulative sum check, and Twin Plot(2D) deliver reliable chemistry analyzer performance across routine and stat testing. HL7-compatible bi-directional LIS connectivity with LAN port access supports structured data handling for clinical diagnostics, histopathology, and research institutes. Compatible with Windows 7/8/10, 32 or 64-bit, with external printer support and multiple reporting modes for seamless lab workflow integration. Explore EziLab's auto chemistry analyzer range and analyzers for related products.
Specifications
| Throughput | 600 tests/hour |
|---|---|
| Sample Volume | 2 to 70 µl |
| Reagent Volume | 20 to 350 µl |
| Sample Positions | 90 sample positions |
| Reagent Positions | 180 refrigerated reagent positions |
| Wavelength | 340,405,450,510,546,578,630,700nm |
| Absorbance | 0~3.0 Abs |
| Humidity | 30 to 80% |
| Washing | Automatic cuvettes washing |
| Probe Washing | Automatic washing interior and exterior |
| Reagent Cooling | Refrigerated tray with independent switch |
| Cuvettes | 120 reusable cuvettes, optical length 6mm |
| Mixed Probe | Independent stirring |
| Stat Function | Yes |
| Light Source | 12V/30W halogen lamp |
| Spectrophotometry | Post-spectral spectrophotometry |
| Calibration | Linear: K factor, 1-point, 2-point and multipoint linearNon-Linear: Spline, Polygon, Index, Logarithm, Logit-4P,Logit-5 |
| Quality Control | Real-time QC, Westward multi rule, Cumulative sum check, Twin Plot(2D) |
| Software | Windows 7/8/10, 32 or 64bit |
| LIS System | Bi-direction, support HL7 protocol |
| Interface | LAN port access |
| Printer | External, multiple reporting mode available |
| Temperature | 10 to 30°C |
| Temperature Control | 37±0.1°C, real time monitor |
| Water Consumption | Deionized water: 15L/H |
| Power Supply | AC220V±10%, 60/50Hz,, 110V±10%, 60Hz, 300W |
| External Dimension (W×D×H) | 1167×780×1016 mm |
| Package Dimension (W×D×H) | 1348×928×1399 mm |
| Net Weight | 216 kg |
| Gross Weight | 290 kg |
Features