Description
EziLab offers the Double Beam UV-Vis Spectrophotometer EZL-DBS106, a research-grade UV vis spectrometer covering 190 to 900 nm with a continuously adjustable 0.1 to 5 nm bandwidth in 0.1 nm steps. Choose it over single beam models when long scans, kinetics, or method validation demand drift correction, as the reference beam corrects lamp variation, holding stability to ≤0.0001 A/h. Narrow bandwidths separate closely spaced peaks, while wider settings raise light throughput for dilute or turbid samples. Stray light falls to ≤0.005% T at 220 and 360 nm, extending linear absorbance into concentrated samples, and a photomultiplier (PMT) detector adds sensitivity at narrow slits. Wavelength accuracy reaches ±0.3 nm with ≤0.1 nm repeatability, and photometric accuracy holds at ±0.3% T. Tungsten and deuterium lamps cover the UV-visible range, with a mercury lamp for wavelength calibration. PC software control, an automatic cell holder, and a large sample chamber support multi-sample runs and accessories. Pharmaceutical labs run compendial tests and impurity profiling, biotechnology groups study protein and nucleic acid spectra, environmental, petrochemical, and chemical labs analyze trace components, and food, cosmetics, and academic labs run absorbance research. The reference beam justifies its extra cost mostly on kinetic runs lasting an hour or more, so confirm your longest run before comparing the Spectrophotometer category and Double Beam UV-Visible Spectrophotometer range.
Specifications
| Wavelength Range | 190 to 900 nm |
|---|---|
| Spectral Bandwidth | Continuously adjustable from 0.1 nm to 5 nm with 0.1 nm interval |
| Wavelength Accuracy | ± 0.3 nm |
| Wavelength Repeatability | Less than or equal to 0.1 nm |
| Photometric Accuracy | ± 0.3 % T |
| Stability | Less than or equal to 0.0001 A / h |
| Stray Light | Less than or equal to 0.005 % T at 220 nm & 360 nm |
| Light Source | Tungsten, Deuterium and Mercury Lamp |
| Optical System | Double Beam |
| Control Mode | PC Software Controlled |
| Detector | Photomultiplier (PMT) |
| Power Requirements | AC 110 / 220 V, 50 / 60 Hz |
Features
| Feature Area | Description |
| Optical System | Double beam optical system with a reference beam. |
| Light Sources | Tungsten, deuterium, and mercury lamps. |
| Detector | Photomultiplier detector. |
| PC Control | Control through PC software. |
| Sample Chamber | Large sample chamber with an automatic cell holder. |
Standard Accessories
Spectrophotometer | 1 unit |
1 cm Glass Cuvette | 4 pieces |
1 cm Quartz Cuvette | 2 pieces |
Power Cord | 1 piece |
User’s Manual | 1 piece |
Dust Cover | 1 piece |
Optional Accessories
1 | Cell Holders |
2 | Control Units |
3 | Lamps |
4 | Glass Cuvette with Lid |
5 | Quartz Cuvette with Lid |
6 | Micro Cuvette |
Applications