EziLab offers the Hematology Analyzer EZL-HA106, an automated hematology analyzer that pairs scatter, fluorescence, and cube technology for three-dimensional cell differentiation. It runs 80 CD tests per hour, 45 CDR tests per hour, or 40 CD+ESR tests per hour, and CD mode needs only 25 µL of whole blood. RBC and PLT use focusing flow DC impedance, HGB uses colorimetry, and ESR uses photometry. A floating screen design, onboard LH lyse, and 150,000-result storage round out the unit. Hospitals, clinical laboratories, and diagnostic centers use this complete blood count machine to screen for infection, anemia, and hematological disorders. The report covers a five-part WBC differential, reticulocytes, NRBC, IPF, MPV, and RDW indices, supporting routine checks and disease monitoring. Because it works as a CBC machine and ESR analyzer in one, labs skip a separate ESR instrument. Reference laboratories and hospital networks count on the 80 tests per hour throughput to clear heavy sample loads. Blood banks keep numeric and graphical results on the unit instead of exporting after each run, and academic research programs draw on that history for longitudinal studies. High-volume diagnostic settings gain the most from it. Combined CBC and ESR in one unit saves bench space, so see where it fits among the models on the Analyzer and Hematology Analyzer pages.
| Measuring Principle | Scatter, Fluorescence, and Cube technology |
|---|---|
| Throughput | CD80t/h CDR45t/h CD+ESR40t/h |
| RBC, PLT | Focusing Flow-DC Impedance Method |
| HGB | Colorimetric method |
| ESR | Photometric method |
| Report Parameters | WBC Bas# Bas% Neu# Neu% Eos# Eos% Lym# Lym% Mon# Mon% IMG# IMG% RET% *RET# *RHE* IRF* LFR* MFR* HFR* RBC HGB MCV MCH MCHC RDW-CV RDW-SD HCT NRBC# NRBC% PLT PLT-I PLT-H PLT-O* MPV PDW PCTP-LCR P-LCC IPF ESR |
| Sample Volume | CD (whole blood): 25ul CD+ESR |
| Reagents | Build-in LH Lyse, External Diluent, Probe Cleaner for maintenance |
| Storage | Up to 150,000 results including numeric and graphical information |
| Working Temperature | 10℃ to 35℃ |
| Relative Humidity | 30% to 85% |
| Atmospheric Pressure | 70.0 KPa to 106.0 KPa |
| Dimension ( D × W × H) | 840 × 655 × 600 mm |
| Weight | Less than equal to 70.6Kg |
| Feature Area | Description |
| Measuring Principle | Uses scatter, fluorescence and cube technology, with focusing flow DC impedance for RBC and PLT and colorimetric HGB measurement. |
| Throughput | Runs at 80 t/h in CD mode, 45 t/h in CDR mode and 40 t/h in CD+ESR mode. |
| Sample Volume | Needs 25 µL of whole blood in CD mode. |
| Data Storage | Stores up to 150,000 results in numeric and graphical form. |
| Reagents | Built-in LH lyse, with external diluent and probe cleaner. |