EziLab supplies the Low Speed Refrigerated Centrifuge EZL-LRC109 for pharmaceutical and research laboratories that need a 4x750mL rotor with accel/decel control at the same 6000rpm speed and 6080 RCF as the non-refrigerated standard low speed centrifuge in this catalog. This lab centrifuge combines that familiar force output with a larger 750mL tube format than the standard 600mL rotor, plus programmable acceleration and deceleration control that softens the ramp for shear-sensitive samples during spin-up and spin-down phases specifically. That accel/decel feature matters for pharmaceutical and research protocols involving delicate cell suspensions or density gradients where sudden speed changes could disrupt sample integrity, giving finer control than a standard fixed-ramp centrifuge provides. The 4x750mL capacity accommodates larger sample volumes than the base 4x600mL rotor while maintaining the same familiar 6000rpm/6080 RCF force profile many labs already work with. Pharmaceutical and research labs needing gentler ramp control at this established force level, with slightly larger tube capacity, get that combination here. See the Lab Centrifuge and Low Speed Refrigerated Centrifuge ranges for gentle-ramp large-batch separation needs across USA pharmaceutical and research laboratory settings.
| Maximum Speed | 6000rpm |
|---|---|
| Maximum RCF | 60800 × g |
| Maximum Capacity | 4 × 750 ml |
| Timer Range | 1 to 99 mins 59 sec adjustable |
| Speed Accuracy | ±10 r/min |
| Noise Level | Less than equal to 58 dB(A) |
| Acceleration/Deceleration | 1 to 10 |
| Dimensions (W×D×H) | 670 × 740 × 370 mm |
| Wight (without rotor) | 100Kg |
Microprocessor based control
Corrosion resistant buckets
Maintenance free AC motor
Durable rotor design
Vibration free operation
Low Speed Refrigerated Centrifuge EZL-LRC 109 is ideal for medical laboratories, cell biology studies and pharmaceutical laboratories for separating substances of varying densities. It is also used for drug formulation studies and stability testing of temperature-sensitive compounds.
Rotor Type | Capacity (ml) | Maximum Speed (r/min) | Maximum RCF (×g) |
Angle Rotor 01 | 12 × 15/10/5 mL | 6000 r/min | 4588 × g |
Swing rotor 01 | Steel frame rotor | 5000 r/min | 4752 × g |
Swing frame 02 | 4 × 100 mL | 5000 r/min | 4752 × g |
Swing frame 03 | 4 × 50 mL | 5000 r/min | 4752 × g |
Swing rotor 02 | Steel frame rotor | 4000 r/min | 3041 × g |
Swing frame 04 | 4 × 2 × 100 mL | 4000 r/min | 3041 × g |
Swing frame 05 | 4 × 2 × 50 mL | 4000 r/min | 3041 × g |
Swing frame 06 | 4 × 8 × 15/10/5mL | 4000 r/min | 3041 × g |
Swing bucket 01 | 4 × 18 × 2/5 mL | 4000 r/min | 2773 × g |
Swing bucket 02 | 4 × 600 mL | 4000 r/min | 3354 × g |
Swing bucket 03 | 4 × 500 mL | 4000 r/min | 3354 × g |
Swing bucket 04 | 4 × 750 mL | 4000 r/min | 3443 × g |
Microplate rotor | 2 × 2 × 96 hole | 4200 r/min | 2860 × g |
Adapter Type | Capacity (ml) | Maximum Speed (r/min) | Maximum RCF (×g) |
Adapter 01 | 12 × 2mL | 6000 r/min | 4588 × g |
Adapter 02 | 4 × 15/10 mL | 5000 r/min | 4752 × g |
Adapter 03 | 4 × 2 × 15/10 mL | 4000 r/min | 3041 × g |
Rack | 4 × 12 × 5/2 mL | 4000 r/min | 3041 × g |
Adapter 05 | 4 × 25 ×5/2 mL | 4000 r/min | 3354 × g |
Adapter 06 | 4 × 12 × 15/10 mL | 4000 r/min | 3354 × g |
Adapter 07 | 4 × 5 × 50 mL | 4000 r/min | 3354 × g |
Adapter 08 | 4 × 4 × 100 mL | 4000 r/min | 3354 × g |
Adapter 09 | 4 × 17 × 5/2 mL | 4000 r/min | 3354 × g |
Adapter 10 | 4 × 8 × 15/10 mL | 4000 r/min | 3354 × g |
Adapter 11 | 4 × 3 × 50 mL | 4000 r/min | 3354 × g |
Adapter 12 | 4 × 100 mL | 4000 r/min | 3354 × g |
Adapter 13 | 4 × 26 × 5/2 mL | 4000 r/min | 3443 × g |
Adapter 14 | 4 × 13 × 15/10 mL | 4000 r/min | 3443 × g |
Adapter 15 | 4 × 5 × 50 mL | 4000 r/min | 3443 × g |
Adapter 16 | 4 × 3 × 100ml | 4000 r/min | 3443 × g |
Adapter 17 | 2 × 32 × 1.5ml | 4200 r/min | 2860 × g |
The Low Speed Centrifuge EZL-LRC109 is equipped with advanced safety features to protect both users and samples. Overspeed protection automatically prevents the rotor from exceeding its safe operational limits, thereby minimizing the risk of accidents. Its corrosion-resistant construction adds another layer of safety, allowing the unit to withstand exposure to common laboratory reagents without degrading. Additionally, smooth acceleration and deceleration settings reduce sample disturbance, preventing spills and preserving the integrity of delicate samples. These combined features give laboratories the confidence to operate the centrifuge safely and reliably, even with sensitive materials.
Ezilab’s Low Speed Centrifuge EZL-LRC109 is designed with user convenience as a priority. Its intuitive LCD display provides clear, real-time information on speed, time, and other operational parameters, making it easy to monitor and adjust settings as needed. The interface allows parameter adjustments without interrupting the run, which saves valuable time in busy labs. A wide time range setting offers flexibility, accommodating both quick spins and extended protocols. Furthermore, the easy rotor replacement system simplifies workflow transitions, making the centrifuge well-suited for labs with diverse applications.
Our Low Speed Centrifuge EZL-LRC109 is built to manage larger sample volumes with efficiency and consistency. Its frequency converter motor ensures stable performance, even during demanding operations with higher capacities. This capability is particularly beneficial for clinical laboratories, research institutes, and teaching facilities that often process multiple or bulk samples at once. The centrifuge’s design reduces the risk of imbalance while maintaining accuracy in separation. By combining high capacity with reliable results, it helps laboratories improve throughput without compromising quality.
Our Low Speed Centrifuge EZL-LRC109 is engineered for long-term performance with minimal maintenance needs. The corrosion-resistant design prevents wear and tear from frequent exposure to chemicals, ensuring a longer lifespan. Its advanced, brushless motor significantly reduces the need for routine servicing compared to traditional centrifuges. Basic maintenance involves regular cleaning of the rotor chamber and verifying sample balance before each use to avoid undue strain on the equipment. With these simple steps, the centrifuge continues to deliver safe, accurate, and dependable performance over the years.
Ezilab’s Low Speed Centrifuge EZL-LRC109 plays a key role in making operation more efficient and reliable. It provides a bright, clear, and easy-to-read view of essential parameters, allowing users to track speed, time, and operational status with accuracy. Real-time adjustments can be made without pausing the run, reducing downtime and enhancing productivity. This digital interface minimizes errors that are common with manual settings, ensuring precision in every cycle. Especially in fast-paced laboratory environments, the LCD display adds both convenience and confidence to daily operations.
The Low Speed Centrifuge EZL-LRC109 is critical for protecting sensitive samples. A controlled start-up minimizes shock to delicate biological materials, while a gradual slowdown prevents resuspension or spillage of separated components. This is particularly valuable when working with fragile cells, fine precipitates, or sensitive biomolecules. By allowing customization of these parameters, the centrifuge ensures both sample integrity and operator safety. Additionally, this feature reduces mechanical stress on the rotor and motor, contributing to the long-term durability of the equipment.