Description

EziLab supplies the Low Speed Refrigerated Centrifuge EZL-LRC109 for pharmaceutical and research laboratories that need a 4x750mL rotor with accel/decel control at the same 6000rpm speed and 6080 RCF as the non-refrigerated standard low speed centrifuge in this catalog. This lab centrifuge combines that familiar force output with a larger 750mL tube format than the standard 600mL rotor, plus programmable acceleration and deceleration control that softens the ramp for shear-sensitive samples during spin-up and spin-down phases specifically. That accel/decel feature matters for pharmaceutical and research protocols involving delicate cell suspensions or density gradients where sudden speed changes could disrupt sample integrity, giving finer control than a standard fixed-ramp centrifuge provides. The 4x750mL capacity accommodates larger sample volumes than the base 4x600mL rotor while maintaining the same familiar 6000rpm/6080 RCF force profile many labs already work with. Pharmaceutical and research labs needing gentler ramp control at this established force level, with slightly larger tube capacity, get that combination here. See the Lab Centrifuge and Low Speed Refrigerated Centrifuge ranges for gentle-ramp large-batch separation needs across USA pharmaceutical and research laboratory settings.

Specifications

Maximum Speed 6000rpm
Maximum RCF 60800 × g
Maximum Capacity 4 × 750 ml
Timer Range 1 to 99 mins 59 sec adjustable
Speed Accuracy ±10 r/min
Noise Level Less than equal to 58 dB(A)
Acceleration/Deceleration 1 to 10
Dimensions (W×D×H) 670 × 740 × 370 mm
Wight (without rotor) 100Kg

Features

  • Microprocessor based control
  • Corrosion resistant buckets
  • Maintenance free AC motor
  • Durable rotor design
  • Vibration free operation

Applications

  • Low Speed Refrigerated Centrifuge EZL-LRC 109 is ideal for medical laboratories, cell biology studies and pharmaceutical laboratories for separating substances of varying densities. It is also used for drug formulation studies and stability testing of temperature-sensitive compounds.

Rotor Selection

Rotor Type

Capacity (ml)

Maximum Speed (r/min)

Maximum RCF (×g)

Angle Rotor 01

12 × 15/10/5 mL

6000 r/min

4588 × g 

Swing rotor 01

Steel frame rotor

5000 r/min

4752 × g

Swing frame 02

4 × 100 mL

5000 r/min

4752 × g

Swing frame 03

4 × 50 mL

5000 r/min

4752 × g

Swing rotor 02

Steel frame rotor

4000 r/min

3041 × g

Swing frame 04

4 × 2 × 100 mL

4000 r/min

3041 × g

Swing frame 05

4 × 2 ×  50 mL

4000 r/min

3041 × g

Swing frame 06

4 × 8 × 15/10/5mL

4000 r/min

3041 × g

Swing bucket 01

4 × 18 × 2/5 mL

4000 r/min

2773 × g

Swing bucket 02

4 × 600 mL

4000 r/min

3354 × g

Swing bucket 03

4 × 500 mL

4000 r/min

3354 × g

Swing bucket 04

4 × 750 mL

4000 r/min

3443 × g

Microplate rotor

2 × 2 × 96 hole

4200 r/min

2860 × g

Adapter Selection

Adapter Type 

Capacity (ml) 

Maximum Speed (r/min) 

Maximum RCF (×g) 

Adapter 01

12 × 2mL

6000 r/min

4588 × g

Adapter 02

4 × 15/10 mL

5000 r/min

4752 × g

Adapter 03

4 × 2 × 15/10 mL

4000 r/min

3041 × g

Rack

4 × 12 × 5/2 mL

4000 r/min

3041 × g

Adapter 05

4 × 25  ×5/2 mL

4000 r/min

3354 × g

Adapter 06

4 × 12 × 15/10 mL 

4000 r/min

3354 × g

Adapter 07

4 × 5 × 50 mL 

4000 r/min

3354 × g

Adapter 08

4 × 4 × 100 mL

4000 r/min

3354 × g

Adapter 09

4 × 17 × 5/2 mL

4000 r/min

3354 × g

Adapter 10

4 × 8 × 15/10 mL

4000 r/min

3354 × g

Adapter 11

4 × 3 × 50 mL 

4000 r/min

3354 × g

Adapter 12

4 × 100 mL

4000 r/min

3354 × g

Adapter 13

4 × 26 × 5/2 mL

4000 r/min

3443 × g

Adapter 14

4 × 13 × 15/10 mL

4000 r/min

3443 × g

Adapter 15

4 × 5 × 50 mL

4000 r/min

3443 × g

Adapter 16

4 × 3 × 100ml

4000 r/min

3443 × g

Adapter 17

2 × 32 × 1.5ml

4200 r/min

2860 × g