EziLab offers the Horizontal Autoclave EZL-CH85, a large-capacity steam sterilizer built to process high-volume loads of instruments, glassware, culture media, and general lab materials in a single cycle. Its 500 L chamber, sized at Φ700 × 1300 mm, operates at 134°C and 0.22 MPa working pressure, powered by an 18 kW heater for efficient heat distribution throughout the load. Programmable sterilization and drying phases each run from 0 to 60 minutes, so loads come out ready for immediate use. A dissolving mode from 40 to 90°C and warming mode from 40 to 60°C, each adjustable up to 48 hours, support media preparation and agar melting. Safe door locking, over-temperature safeguards, and over-pressure protection keep operators safe, while a user-friendly interface simplifies cycle setup. The 1800 × 900 × 1820 mm frame and 470 kg net weight suit permanent installation in central sterile service areas. In industrial settings, hospitals use this autoclave machine for bulk sterilization of surgical instruments and dressings without repeated cycles. Pharmaceutical plants sterilize glassware and process components, microbiology laboratories sterilize culture media and lab materials, and food industry labs prepare sterile equipment for quality testing. Installation planning, from floor loading to the 18 kW power feed, deserves the same attention as chamber size when you compare the Autoclave category and Horizontal Autoclave range.



Quantity:
$8866
Volume of Chamber 500 L
Chamber Size Φ 700 × 1300 mm
Working temperature 134 °C
Working pressure 0.22 MPa
Time of Sterilization 0 to 60 minutes
Time of Drying 0 to 60 minutes
Dissolving Temperature 40˚C to 90˚C
Dissolving Time 0 minutes to 48 hours
Warming Temperature 40˚C to 60˚C
Warming Time 0 minutes to 48 hours
Dimension 1800 × 900 × 1820mm
Net Weight 470kg
Gross Weight 580 kg
  • Safe door locking

  • Over-temperature safeguard

  • Over-pressure protection

  • Efficient heat distribution

  • User friendly interface

•Used in hospitals for bulk sterilization of surgical instruments and dressings.
•Applied in central sterile service areas for permanently installed, high-volume instrument processing.
•Employed in pharmaceutical plants to sterilize glassware and process components.
•Suited to microbiology laboratories for sterilizing culture media and lab materials, including media preparation and agar melting.
•Supports food industry labs in preparing sterile equipment for quality testing.
•Handles glassware and media that tolerate high temperatures in research facilities and laboratories.

Frequently Asked Questions

The Horizontal Autoclave EZL-CH85 is designed to handle higher loads, making it suitable for laboratories, hospitals, and research facilities that require frequent sterilization of bulk instruments, media, or glassware. The horizontal chamber design allows more efficient use of space while accommodating larger volumes. This makes it ideal for institutions where sterilization demand is high. By providing consistent sterilization performance, it supports both daily workflows and critical safety standards.

Our Horizontal Autoclave EZL-CH85 prioritizes user safety with built-in mechanisms like automatic pressure regulation, temperature monitoring, and emergency shut-off systems. These features help prevent over-pressurization or overheating, reducing the risk of accidents. The secure chamber lock ensures that the unit cannot be opened while still under pressure. This design gives operators confidence in daily use while meeting regulatory safety expectations.

Ezilab’s Horizontal Autoclave EZL-CH85 is optimized for steam sterilization, which is most effective for glassware, surgical instruments, and media that tolerate high temperatures. For heat-sensitive items, it may not be the best fit, as steam can damage delicate plastics or specialized coatings. However, with appropriate cycle settings, it can accommodate a wide range of robust materials. Laboratories should evaluate sample compatibility before selecting sterilization parameters.

Our Horizontal Autoclave EZL-CH85 requires routine checks such as cleaning the chamber, inspecting gaskets, and monitoring water quality used for steam generation. Preventive maintenance helps extend the life of the autoclave and ensures consistent performance. The straightforward design makes servicing simple, reducing downtime for laboratories. Regular care ensures both operator safety and long-term reliability of the equipment.

Ezilab’s Horizontal Autoclave EZL-CH85 is designed with insulation and intelligent heating controls to optimize energy use. The system minimizes heat loss, ensuring that only the necessary energy is consumed during each cycle. This reduces running costs, which is especially beneficial for laboratories with frequent sterilization demands. Over time, the energy efficiency contributes to both sustainability and cost savings.

Our Horizontal Autoclave EZL-CH85 supports a wide range of applications, from sterilizing surgical tools and dressings to preparing culture media and laboratory glassware. Its large chamber size accommodates diverse load types without compromising sterilization quality. This flexibility makes it suitable for medical, research, and industrial labs alike. Its versatility ensures that labs can rely on one system for multiple needs.