Description
EziLab supplies the Low Speed Refrigerated Centrifuge EZL-LRC110 for pharmaceutical and research laboratories that need force very close to the entry-tier 4,640 RCF unit in this catalog, at a marginally higher 5500rpm and 4,675 RCF. This centrifuge machine sits essentially at the bottom of this category's force progression alongside the original entry-level model, with a temperature range of -20°C to 40°C keeping temperature-sensitive samples stable throughout the run. That minimal difference from the entry-tier unit's 4,640 RCF means the practical choice between the two comes down to sourcing channel or listing preference rather than any meaningful separation performance difference, since both deliver essentially equivalent gentle, controlled separation for blood plasma work, cell culture processing, and enzyme-sensitive sample handling. Pharmaceutical and research labs running routine low-force refrigerated separation at this baseline tier get consistent performance from either this or the original entry-level configuration in this catalog. See the Centrifuge and Low Speed Refrigerated Centrifuge ranges for entry-tier temperature-controlled separation needs across USA pharmaceutical and research laboratory settings.
Specifications
| Maximum Speed | 5500 rpm |
|---|---|
| Maximum RCF | 4675 × g |
| Maximum Capacity | 4 × 250 ml |
| Timer Range | 1 to 99 mins 59 sec adjustable |
| Speed Accuracy | ±10 r/min |
| Temperature Range | -20˚C to 40˚C |
| Temperature Accuracy | ± 1.0℃ |
| Noise Level | Less than equal to 58 dB(A) |
| Dimensions (W×D×H) | 680 × 600 × 395 mm |
| Net Weight | 108 Kg |
Features
Applications
Rotor Selection
Rotor Type | Capacity (ml ) | Maximum Speed (r/min) | Maximum RCF (×g) |
Angle Rotor 01 | 6 × 50ml | 5500 rpm | 3645 × g |
Angle Rotor 02 | 24 × 15ml | 5500 rpm | 4675 × g |
Angle Rotor 03 | 40 × 15ml | 5000 rpm | 4191× g |
Pipe Rack 01 | 4 × 50 ml | 4000 rpm | 2951 × g |
Pipe Rack 02 | 4 × 100 ml | 4000 rpm | 2951 × g |
Pipe Rack 03 | 8 × 50ml | 4000 rpm | 2951 × g |
Pipe Rack 04 | 8 × 100ml | 4000 rpm | 2951 × g |
Pipe Rack 05 | 16 × 10 /15 ( Optional) | 4000 rpm | 2951 × g |
Pipe Rack 06 | 24 × 10/15ml (Optional ) | 4000 rpm | 2951 × g |
Pipe Rack 07 | 32 × 10/15ml (Optional ) | 4000 rpm | 2951 × g |
Pipe Rack 08 | 48× 2 to 7ml (Blood Collection tube ) | 4000 rpm | 2951 × g |
Pipe Rack 09 | 64 × 5ml ( Blood Collection tube) | 4000 rpm | 2951 × g |
Swing Out Rotor 01 | 4 × 250 ml (Round bottom) | 4000 rpm | 3040 ×g |
Swing Out Rotor 02 | 4 × 250 ml (Round bottom) / (with biosafety lid ) | 4000 rpm | 3040 ×g |
Swing Out Rotor 03 | Auto uncap 64 × 2 to 7ml (Blood collection tube) | 4000 rpm | 3040 ×g |
Swing Out Rotor 04 | 4 × 250ml square bucket includes: Adapter 4×4×50ml(conical bottom) Adapter 4×10×15ml(conical bottom) | 4000 rpm | 3040 ×g |
Swing Out Rotor 05 | Micro-plate 2×2×96 hole | 4000 rpm | 2057× g |
Adapter Selection
Adapter Type | Capacity (ml) | Maximum Speed (r/min) | Maximum RCF (×g) |
Adapter 01 | 4 × 1 × 250ml Flat bottom | 4000 rpm | 3040 × g |
Adapter 02 | 4 × 2 × 100ml Round bottom | 4000 rpm | 3040 × g |
Adapter 03 | 4 × 10 × 10/15ml Conical bottom | 4000 rpm | 3040 × g |
Adapter 04 | 4 × 12 × 10ml High speed round bottom | 4000 rpm | 3040 × g |
Adapter 05 | 4 × 12 × 5ml High speed round bottom buckle cap tube | 4000 rpm | 3040 × g |
Adapter 06 | 4 ×16 × 1.5 /2ml | 4000 rpm | 3040 × g |
Adapter 07 | 4 × 12 × 10ml Blood collection tube | 4000 rpm | 3040 × g |
Adapter 08 | 4 × 18 × 2 to 7ml Blood collection tube | 4000 rpm | 3040 × g |