Low Speed Refrigerated Centrifuge EZL-LRC110 delivers a maximum speed of 5500 rpm ensuring efficient separation of the sample. It uses microcomputer control and an AC frequency conversion brushless motor for stable speed. Equipped with large LCD display for real time parameter viewing. The automatic electronic door lock ensures user safety and sample protection during operation. Our Low Speed Refrigerated Centrifuge is ideal for routine sample separation in clinical and research laboratories.
| Maximum Speed | 5500 rpm |
|---|---|
| Maximum RCF | 4675 × g |
| Maximum Capacity | 4 × 250 ml |
| Timer Range | 1 to 99 mins 59 sec adjustable |
| Speed Accuracy | ±10 r/min |
| Temperature Range | -20˚C to 40˚C |
| Temperature Accuracy | ± 1.0℃ |
| Noise Level | Less than equal to 58 dB(A) |
| Power Supply | AC 220V 50Hz 10A 1000W |
| Dimensions (W×D×H) | 680 × 600 × 395 mm |
| Net Weight | 108 Kg |
Five program groups
Large storage capacity
Brushless motor drive
Anti-corrosion coating
Noise reduction system
Low Speed Refrigerated Centrifuge EZL-LRC110 widely used in clinical diagnostics, biochemistry, and pharmaceutical laboratories where temperature-sensitive separations are essential for accurate analytical results.
Rotor Type | Capacity (ml ) | Maximum Speed (r/min) | Maximum RCF (×g) |
Angle Rotor 01 | 6 × 50ml | 5500 rpm | 3645 × g |
Angle Rotor 02 | 24 × 15ml | 5500 rpm | 4675 × g |
Angle Rotor 03 | 40 × 15ml | 5000 rpm | 4191× g |
Pipe Rack 01 | 4 × 50 ml | 4000 rpm | 2951 × g |
Pipe Rack 02 | 4 × 100 ml | 4000 rpm | 2951 × g |
Pipe Rack 03 | 8 × 50ml | 4000 rpm | 2951 × g |
Pipe Rack 04 | 8 × 100ml | 4000 rpm | 2951 × g |
Pipe Rack 05 | 16 × 10 /15 ( Optional) | 4000 rpm | 2951 × g |
Pipe Rack 06 | 24 × 10/15ml (Optional ) | 4000 rpm | 2951 × g |
Pipe Rack 07 | 32 × 10/15ml (Optional ) | 4000 rpm | 2951 × g |
Pipe Rack 08 | 48× 2 to 7ml (Blood Collection tube ) | 4000 rpm | 2951 × g |
Pipe Rack 09 | 64 × 5ml ( Blood Collection tube) | 4000 rpm | 2951 × g |
Swing Out Rotor 01 | 4 × 250 ml (Round bottom) | 4000 rpm | 3040 ×g |
Swing Out Rotor 02 | 4 × 250 ml (Round bottom) / (with biosafety lid ) | 4000 rpm | 3040 ×g |
Swing Out Rotor 03 | Auto uncap 64 × 2 to 7ml (Blood collection tube) | 4000 rpm | 3040 ×g |
Swing Out Rotor 04 | 4 × 250ml square bucket includes: Adapter 4×4×50ml(conical bottom) Adapter 4×10×15ml(conical bottom) | 4000 rpm | 3040 ×g |
Swing Out Rotor 05 | Micro-plate 2×2×96 hole | 4000 rpm | 2057× g |
Adapter Type | Capacity (ml) | Maximum Speed (r/min) | Maximum RCF (×g) |
Adapter 01 | 4 × 1 × 250ml Flat bottom | 4000 rpm | 3040 × g |
Adapter 02 | 4 × 2 × 100ml Round bottom | 4000 rpm | 3040 × g |
Adapter 03 | 4 × 10 × 10/15ml Conical bottom | 4000 rpm | 3040 × g |
Adapter 04 | 4 × 12 × 10ml High speed round bottom | 4000 rpm | 3040 × g |
Adapter 05 | 4 × 12 × 5ml High speed round bottom buckle cap tube | 4000 rpm | 3040 × g |
Adapter 06 | 4 ×16 × 1.5 /2ml | 4000 rpm | 3040 × g |
Adapter 07 | 4 × 12 × 10ml Blood collection tube | 4000 rpm | 3040 × g |
Adapter 08 | 4 × 18 × 2 to 7ml Blood collection tube | 4000 rpm | 3040 × g |