EziLab offers the Tabletop Dissolved Oxygen Meter EZL-TDO121, a benchtop DO meter that reports oxygen concentration, saturation and temperature on a 6.5-inch color touchscreen. A polarographic electrode reads 0.00 to 20 mg/L at 0.01 or 0.1 steps within ±0.3%, saturation from 0 to 200% within ±2% of full scale, and temperature from 0 to 100 °C within ±0.1 °C, with 90% response inside 30 seconds and drift held to ±0.07 mg/L per hour. Automatic compensation for temperature, salinity up to 50 g/L and barometric pressure from 80 to 105 kPa removes manual corrections, a membrane integrity check and self-diagnosis catch failing caps, and the screw-on diaphragm cap replaces the membrane. Five hundred time-stamped readings export over USB, Bluetooth or wireless printing, and the IP54 housing survives wet benches. Power stations, wastewater treatment works, environmental protection agencies, aquaculture farms, breweries and university environmental departments use this dissolved oxygen meter for daily checks. Typical measurements include boiler feed water scavenging checks, aeration tank monitoring, effluent compliance, fish pond levels and fermentation uptake. Choose it over a handheld DO probe when logged, traceable results are required. Polarographic electrodes consume oxygen at the membrane, which makes still water read low; stir at a steady rate for a fair value. For related meters, start at Lab Equipment and continue to Water Quality Analyzer.
| Parameters | Concentration, Saturation, Temperature |
|---|---|
| DO Range | 0.00 to 20 mg/L (ppm) |
| Resolution | 0.01/0.1 |
| DO Accuracy | ± 0.3 % |
| DO Saturation | 0.0 to 200 % |
| Saturation Resolution | 0.001 |
| Saturation Accuracy | ± 2.0 % FS |
| Temperature Measuring Range | 0 °C to 100 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ± 0.1 °C |
| Temperature Compensation Range | 0 °C to 100 °C ( Automatic) |
| Salinity Compensation Range | 0.0 to 50.0 g/L |
| Pressure Compensation Range | 80 kPa to 105 kPa (Automatic) |
| Pressure Resolution | 1 |
| Pressure Accuracy | ± 2 % |
| Stability | ± 0.07 mg/L/1h |
| Response Time | ≤ 30 s (25 °C, 90 % Response) |
| Feature Area | Description |
| Display | A large colour capacitive screen shows all parameters. |
| Compensation | Automatic compensation covers temperature, salinity and pressure. |
| Data Handling | Data storage comes with USB export, Bluetooth and wireless printing. |
| Electrode | A polarographic DO electrode reads temperature, salinity and dissolved oxygen. |
| Membrane Cap | A combined diaphragm cap swaps the membrane by screwing on a new cap, with a membrane integrity function. |
DO Meter LO-TDOM200 Series 1 unit
Composite DO electrode 1 pc
Rotary electrode holder 1 pc
12V Power adapter 1pc
Membrane cap 3 pcs
DO electrode electrolyte (30ml) 1 bottle
Brief operating manual 1 copy