Water Quality Analyzers

Ezilab Water Quality Analyzers deliver accurate and consistent measurements, ensuring reliable results. They are equipped with touchscreens for users to read and interpret data. The data storage capacity facilitates the record-keeping of samples ranging from 200 to 10,000 sets. Their USB data transfer enables operational efficiency and data security. Our Water Quality Analyzers have energy efficiency features that enhance effective environmental monitoring across various applications.

  • Accuracy: ≤±5%
  • Repeatability: 0.03
  • Absorbance Detection Range: 0 to 3.5 Abs
  • Optical Path Stability: ≤±0.002Abs/30 min
  • Capacity: Can treat 4 samples at the same time
  • Temperature Control Range: RT to 180°C
  • Reaction Temperature: 50°C to 180°C
  • Temperature Control Accuracy: ≤ ± 0.1°C
  • Dissolved Oxygen: 0 to 20.00 mg/L (ppm), 0 to 200.0 %, 0.1/0.01 mg/L (ppm), 1/0.1 %, ≤ 30 s (25 °C, 90 % Response), ≤ 0.1 mg/L, 0 °C to 100 °C (Automatic), 0 to 45 ppt (Automatic), 66 to 200 kPa (Manual)
  • Working Conditions: 5 °C to 35 °C, ≤ 85 %
  • Power: 2 AA batteries (1.5 V)
  • Dimensions (W×D×H): 160×90×30 mm (Instrument), 480×300×60 mm (With Packing)
  • Parameters: Concentration, Saturation, Temperature
  • DO Range: 0.00 to 20 mg/L (ppm)
  • Resolution: 0.01/0.1
  • DO Accuracy: ± 0.3 % ± 0.4 mg/L
  • Parameters: Concentration, Saturation, Temperature
  • DO Range: 0.00 to 20 mg/L (ppm)
  • Resolution: 0.01/0.1
  • DO Accuracy: ± 0.3 % , ± 0.4 mg/L
  • Capacity: 16 vials (8+8)
  • Operating Temperature: 45°C to 180°C
  • Temperature Accuracy: ±0.5°C
  • Temperature Resolution: ±0.1°C
  • Measuring Range: 0-20 NTU
  • Indication Error: ±0.3 NTU or ±8% turbidity;±0.3 mg/L or ±8% total suspended solids
  • Accuracy: ±0.1 NTU or ± 5% NTU
  • Repeatability: < 5 NTU, ≤ ± 0.05 NTU ≥ 5 NTU, ≤ ± 1% NTU
  • Measuring Range: 0-1000 NTU
  • Indication Error: ±0.3 NTU or ±8% turbidity;±0.3 mg/L or ±8% total suspended solids
  • Accuracy: ±0.3 NTU or ± 8% NTU
  • Repeatability: < 10 NTU, ≤ ± 0.1 NTU ≥ 10 NTU, ≤ ± 1% NTU
  • Measuring Range: 0 to 1000 mg/L
  • Indication Error: ±0.3 NTU or ±8% turbidity;±0.3 mg/L or ±8% total suspended solids
  • Accuracy: ± 0.3 mg/L or ±8% mg/L
  • Repeatability: < 5 NTU, ≤ ± 0.05 NTU ≥ 5 NTU, ≤ ± 1% NTU
  • Test Item: COD, Ammonia Nitrogen, Phosphorous, Nitrogen
  • Method: COD: Rapid digestion spectrometry Total Phosphorous: Rapid digestion spectrophotometry of ammonium molybdate
    Total Nitrogen: Potassium per-sulfate rapid digestion spectrophotometry
  • Measuring Range: COD: 0-15000 mg/L
    Ammonia Nitrogen: 0-100 mg/L
    Total Phosphorous: 0-20 mg/L
    Total Nitrogen: 0-500 mg/L
  • Minimum Measurement: COD: 10 mg/L
    Ammonia Nitrogen: 0.05 mg/L
    Total Phosphorous: 0.02 mg/L
    Total Nitrogen: 0.5 mg/L
  • Wavelength Range: 420 nm to 620 nm
  • Absorbance Monitoring Range: 0 to 3.0 Abs
  • Absorbance Resolution: 0.001 Abs
  • Temperature: 0 to 50°C
  • Parameters: Concentration, Saturation, Temperature
  • DO Range: 0.00 to 20 mg/L (ppm)
  • Resolution: 0.01/0.1
  • DO Accuracy: ± 0.3 %