Pulse Vacuum Steam Sterilizer EZL-PS91 Catalog

Description

EziLab offers the Pulse Vacuum Steam Sterilizer EZL-PS91, a 360 L pre vacuum autoclave that pulls repeated vacuum pulses before steam enters, so air leaves wrapped packs and lumens first. An imported vacuum pump with its own liquid level balancing and cooling circuit sustains the pulses, the stainless chamber and jacket take plant steam at 0.3 to 0.6 MPa and water at 0.15 to 0.3 MPa, and a PLC touchscreen runs the whole cycle from one key while showing phase status in real time. Remote control is offered, superheat-keeping measures cut energy draw and room air-conditioning load, and sterilant is cooled before discharge. The 982 by 610 by 610 mm chamber sits in a 1350 kg frame on three-phase 380 V. Hospital sterile supply departments, pharmaceutical producers, biological engineering plants, research institutes and large clinical laboratories use this pulse vacuum steam sterilizer for validated high-volume processing. Typical loads include surgical instrument sets, medical dressings, sterile garments, biological products, culture media, fluids and medical waste. Choose it over gravity autoclaves when wrapped and porous loads must meet pre-vacuum standards. Steam and water supply limits sit on the Pulse Vacuum Steam Sterilizer page; other chamber sizes are listed under Pulse Vacuum Sterilizer.

Specifications

Volume 360 L
Water Supply 0.15 – 0.3 Mpa
Steam Supply 0.3 – 0.6 Mpa
Power 24 W
Shape Dimension (L×W×H) 1345×1285×1840 mm
Chamber Dimension (L×W×H) 982×610×610 mm
Voltage AC 380V 50 Hz
Weight 1350 Kg

Features

  • ✓ Imported vacuum pump to ensure stable performance
  • ✓ Liquid level balancing and cooling system to make sure the vacuum pump is always at its best working condition
  • ✓ Chamber and jacket adopt high-quality stainless-steel materializer
  • ✓ PLC touch screen for fully automatic control
  • ✓ One-key smart operation for the whole process
  • ✓ Cycle status and hardware parameters can be monitored in real time
  • ✓ Remote control operation is available
  • ✓ Supper-heat keeping measures are applied to the sterilizer to reduce energy consumption and work load of room air conditioning device
  • ✓ Sterilant is effectively cooled down to reduce heat pollution

Applications

  • ✓ It is frequently used to sterilize medical dressings, biological products, instruments and utensils, sterile suits, medical wastes, fluids, culture media, and other items in medical institutes, pharmaceutical firms, biological engineering, and labs.