EziLab supplies the Horizontal Autoclave EZL-CH105 with a 500L sterilizing chamber, 0.22MPa working pressure, and a 134C working temperature adjustable from 40C upward. Sterilization and drying cycles run 0 to 60 minutes each, heat uniformity holds within 2C, and 18KW power drives a front-loading cylindrical chamber measuring 700mm in diameter by 1300mm deep, weighing 540kg net and 627kg gross. A secure locking system pairs with safety alarms, a silicon rubber door gasket seals the chamber, and an automatic water level shut-off protects the heating element. Clinics and scientific research institutes load the 500L chamber with surgical instruments, glassware, and culture media across larger batches than smaller tabletop units allow, while medical laboratories and microbiological organizations run repeat sterilization cycles on glassed fabrics and mixed lab materials between test rounds. Pharmaceutical facilities favor the 18KW power spec and 500L capacity for higher-volume sterilization runs feeding into production and quality-control workflows, and hospital sterile processing departments use the larger internal footprint to batch more instrument trays per cycle than compact units allow. Laboratories across the USA turn to large-capacity horizontal autoclaves like this one when throughput matters more than bench space. Large batches need volume, so compare Autoclave and Horizontal Autoclave pages.



Quantity:
$9163
Sterilizing capacity 500 L
Working Pressure 0.22MPa
Working Temperature 134°C
Temperature adjust range 40° to 134°C
Time for Sterilization 0 to 60 minutes
Time for drying 0 to 60 minutes
Heat Average ≤ ±2°C
Power Consumption 18KW
Internal Dimensions (ɸ×D) ɸ 700×1300 mm
External Dimensions (L×W×H) 1800×900×1820 mm
Packaging Dimensions (L×W×H) 1850×1050×2050 mm
Net Weight 540 Kg
Gross Weight 627Kg
Feature AreaDescription
Chamber500 L sterilizing capacity, Ø700 × 1300 mm
Temperature134 °C working, adjustable from 40 to 134 °C
Pressure0.22 MPa working pressure
DoorFront-loading cylindrical design, silicone rubber gasket, secure lock with alarms
Water LevelAutomatic water level cut-off
  • Applied by clinics to sterilize surgical instruments in bulk inside the 500 L chamber.
  • Employed by hospital sterile processing departments to run full instrument loads through the Ø700 × 1300 mm chamber.
  • Suited to research institutes for glassware and culture media runs at 134 °C and 0.22 MPa.
  • Supports medical and microbiology labs with repeat cycles between test rounds, followed by 0 to 60 min drying.
  • Handles high-volume pharmaceutical facility runs that need 500 L of sterilizing capacity.
  • Fits large loads that call for automatic water-level cut-off and a gasketed front-loading door with an alarmed lock.