EziLab supplies the Horizontal Autoclave EZL-CH101 with a 150L sterilizing chamber, 0.22MPa working pressure, and a 134C working temperature adjustable from 40C upward. Sterilization and drying cycles run 0 to 60 minutes each, heat average holds within 2C, and 9KW power drives a front-loading chamber measuring 440mm in diameter by 1000mm deep, weighing 278kg net and 320kg gross. Gravity exchange handles air elimination ahead of each cycle, a digital controller adjusts control parameters, and a silicon rubber door gasket pairs with an automatic water level cutoff and audible and visible safety alarms. Clinics and scientific research institutes load the chamber with surgical equipment and culture medium for routine sterilization runs, relying on the gravity-displacement air removal step to clear the chamber before each heating cycle begins. Pharmaceutical labs use the 150L capacity and 9KW power rating for batch sterilization runs feeding into formulation and quality-control workflows, while hospital and clinical sterile processing departments favor the same footprint for instrument turnaround between procedures. Laboratories across the USA pick gravity-type horizontal autoclaves like this one when straightforward air elimination and moderate power draw fit existing utility setups better than steam-jacketed alternatives. Match the air-removal method on the Autoclave and Horizontal Autoclave pages.



Quantity:
$5475
Sterilizing Capacity 150 L
Working Pressure 0.22MPa
Working Temperature 134°C
Temperature Adjust Range 40° to 134°C
Time for Sterilization 0 to 60 minutes
Time for Drying 0 to 60 minutes
Heat Average ≤ ±2°C
Power Consumption 9 KW
Internal Dimensions (ɸ×D) ɸ 440×1000 mm
External Dimensions (L×W×H) 1350×600×1520 mm
Packaging Dimensions (L×W×H) 1560×750×1850 mm
Net Weight 278 Kg
Gross Weight 320Kg
Feature AreaDescription
Chamber150 L sterilizing capacity, front-loading, Ø440 × 1000 mm
Air RemovalGravity displacement
DryingAutomated drying function, time set from 0 to 60 min
ControlDigital temperature control, automatic pressure control switch
AlarmsWater level cut-off, audible and visible alarms
  • Applied by clinics to sterilize surgical equipment with gravity air removal ahead of each cycle.
  • Employed by research institutes for culture media runs under digital temperature control at 134 °C.
  • Suited to pharmaceutical labs for batch sterilization feeding formulation and QC work in the 150 L chamber.
  • Supports hospital sterile processing instrument turnaround through automated drying of 0 to 60 min.
  • Handles runs that call for an automatic pressure control switch alongside adjustable control parameters.
  • Fits routine loads that need audible and visible safety alarms with automatic water-level cutoff.