EziLab’s Horizontal Autoclave EZL-CH104 is a 400L chamber unit with a bore of 700 x 1100 mm, running 105C to 140C sterilization cycles at 0.22 MPa pressure with sterilization times from 0 to 60 minutes and drying cycles up to 48 hours. Dressing drying, over-pressure protection, automatic steam release, and a water shortage alarm work alongside a user-friendly control interface to keep the 520 kg unit running safely through long duty cycles, while dissolving and warming stages run at 40C to 90C and 40C to 60C for media and liquid preparation loads. As a large capacity autoclave built for high daily throughput, this unit suits central sterile supply departments processing surgical instruments, medical tools, and dressings in volume. This industrial autoclave fits hospitals, clinics, and diagnostic laboratories needing a steam sterilizer for bulky loads without multiple short cycles, and its horizontal loading layout keeps trolley workflows fast between rounds. Hospital sterile processing teams and contract sterilization facilities favor a laboratory autoclave of this size when instrument volume outgrows benchtop units, and pharmaceutical manufacturing sites use similar horizontal chambers for bulk sterilization ahead of aseptic filling lines. See the Autoclave and Horizontal Autoclave pages for further specifications and ordering details.



Quantity:
$6674
Volume of Chamber 400 L
Chamber Size Φ 700 × 1100 mm
Working temperature 105 °C to 140 °C
Working pressure 0.22 MPa
Working environment 105 °C to 134 °C
Time of Sterilization 0 to 60 minutes
Time of Drying 0 to 60 minutes
Dissolving Temperature 40˚C to 90˚C
Dissolving Time 0 minutes to 48 hours
Warming Temperature 40˚C to 60˚C
Warming Time 0 minutes to 48 hours
Dimension 1430 × 880 × 1830 mm
Net Weight 520 kg
Gross Weight 530 kg
Feature AreaDescription
Chamber400 L chamber volume with a Φ700 × 1100 mm chamber size.
Pressure0.22 MPa working pressure with automatic steam release.
Cycle TimesSterilization time of 0 to 60 minutes and drying time of 0 to 60 minutes, with a dressing drying function.
Dissolving and WarmingDissolving at 40 to 90 °C and warming at 40 to 60 °C, each up to 48 hours.
ProtectionOver-pressure protection and a water shortage alarm.
  • Applied by central sterile supply departments to process bulky loads in a 400 L chamber.
  • Employed by hospitals for trolley-loaded instrument and dressing runs, using the dressing-drying function.
  • Suited to clinics and diagnostic labs for 0 to 60 min sterilization cycles at 0.22 MPa.
  • Supports contract sterilizers with Φ700 × 1100 mm of chamber space for long cycles.
  • Handles pharmaceutical sites preparing material ahead of aseptic filling, with 0 to 60 min drying afterward.
  • Fits runs that use the 40 to 90 °C dissolving and 40 to 60 °C warming stages, with over-pressure protection and a low-water alarm.