EziLab offers the Horizontal Autoclave EZL-CH103, a front-loading cylindrical steam sterilizer with a 280 L chamber 600 mm across and 1000 mm deep that sterilizes wrapped and unwrapped loads with saturated steam. A 12 kW heater raises the chamber to 134 °C at 0.22 MPa, the digital controller sets any point from 40 to 134 °C and holds it within ±2 °C, and separate sterilization and drying timers each run from 0 to 60 minutes so packs come out fully dry. Overheat and over-pressure cut-outs, visible and audible alarms and a silicone rubber door gasket keep operators and loads safe through repeated cycles. The 391 kg stainless cabinet stands 1780 mm tall on a 1400 mm wide footprint for central sterile departments. Hospitals, surgical centers, dental clinics, microbiology laboratories, pharmaceutical plants and university research facilities use this horizontal autoclave for high-volume sterile processing. Typical loads include surgical instrument trays, textile packs and gowns, glassware and bottles, culture media, biohazard waste and dressing drums. Choose it over vertical top-loading models when long trays and bulky packs must slide in flat at bench height. Hard feed water leaves scale on the heater and chamber; ask the supplier which water quality is required and what any filter or softener costs. The Autoclave category covers other types, while Horizontal Autoclave keeps to front-loading chambers.



Quantity:
$6619
Sterilizing Capacity 280 L
Working Pressure 0.22MPa
Working Temperature 134°C
Temperature adjust range 40° to 134°C
Time for Sterilization 0 to 60 minutes
Time for drying 0 to 60 minutes
Heat Average ≤ ±2°C
Power Consumption 12 KW
Internal Dimensions (ɸ×D) ɸ 600×1000 mm
External Dimensions (L×W×H) 1400×770×1780 mm
Packaging Dimensions (L×W×H) 1680×920×1950 mm
Net Weight 391 Kg
Gross Weight 465Kg
Feature AreaDescription
Overheat ProtectionOverheat protection steps in if the chamber runs hotter than set.
Over-Pressure ProtectionOver-pressure protection guards the vessel during the steam cycle.
AlarmsVisible and audible alarms flag faults during a run.
Digital ControllerA digital temperature controller sets the sterilizing and drying stages.
Door GasketA silicone rubber gasket seals the front-loading door.
  • Supports surgical instrument trays in hospitals.
  • Handles textile packs for dental clinics.
  • Suited to glassware and culture media in microbiology labs.
  • Applied to biohazard waste in pharma facilities.
  • Employed for wrapped or unwrapped loads put in at bench height through the front-loading door.