EziLab offers the Temperature and Humidity Test Chamber EZL-TH169, a 475 L ICH chamber that holds samples at any combination of 0–65 °C and 30–95 %RH for stability and climate testing. A dual refrigeration system on R134a shares the cooling load, a JAKEL circulation fan spreads conditioned air so uniformity stays within ±1 °C, and fluctuation holds to ±0.5 °C at warm setpoints and ±3 %RH throughout. A USB port records temperature and humidity history, and an on-screen log shows trends. The 1250 mm tall workspace takes several shelf levels of bottles, blister packs or boards, and the 2250 W cabinet runs in rooms from 5 to 40 °C. Pharmaceutical stability labs, cosmetics formulators, food and beverage producers, chemical companies, electronics assemblers and packaging developers use this temperature and humidity test chamber to prove shelf life and climate resistance. Typical studies include ICH long-term and accelerated storage, packaging moisture ingress, corrosion and condensation checks on circuit boards, seed viability trials and label adhesion tests. Choose it over a plain incubator when humidity must be controlled, not just temperature. Check your storage points against the 0–65 °C and 30–95 %RH envelope: the usual ICH set (25/60, 30/65, 30/75 and 40/75) sits inside it, while heat stress above 65 °C does not. The Climate Test Chamber category covers other chamber types, and Temperature and Humidity Test Chamber narrows to combined control.



Quantity:
$6850
Volume 475 L
Temperature Range 0 to 65˚C
Operation Temperature 5 to 40 ˚C
Temperature Uniformity ± 1℃
Temperature Fluctuation Low temperature ±1℃, High temperature ±0.5℃
Humidity Control Range 30 to 95 %RH
Humidity Stability ±3 % RH
Refrigerant R134a
Power Rating 2250W
Chamber Size (W × D × H ) 700 × 550 × 1250 mm
Exterior Size (W × D × H ) 880 x 870 x 1895 mm
Net Weight 295 Kg
Gross Weight 358 Kg
Feature AreaDescription
Chamber475 L volume with a 700 × 550 × 1250 mm chamber size.
Temperature and Humidity0 to 65 °C temperature range and 30 to 95 %RH humidity control range, with ±3 %RH humidity stability.
RefrigerationDual refrigeration system using R134a refrigerant.
AirflowJAKEL circulation fan for stable temperature distribution.
DataUSB data recording with an on-screen log of temperature and humidity history.
  • Applied by pharmaceutical labs for stability studies held at 0 to 65 °C and 30 to 95 %RH.
  • Employed by cosmetics teams for shelf-life trials in the 475 L chamber.
  • Suited to food and beverage climate resistance checks with air moved by the circulation fan.
  • Supports chemical storage trials that run on dual R134a refrigeration.
  • Handles electronics corrosion and condensation checks inside the 700 × 550 × 1250 mm chamber.
  • Fits packaging moisture and label adhesion tests that need USB data recording with an on-screen history log.