EziLab offers the Flame Photometer EZL-FP143, a 3-channel microprocessor flame photometer that measures potassium, sodium, and calcium for labs that do not need lithium detection. Choose it over the 4-channel model when lithium therapy monitoring is outside the test menu, at a lower cost. Measurement ranges cover K and Na from 0 to 100 ppm and Ca from 0 to 1000 ppm, with minimum detection limits of 0.1 ppm for K and Na and 2 ppm for Ca. Linear error stays within 0.2 ppm for K, 0.5 ppm for Na, and 2 ppm for Ca, and readings hold within 3% over 15 seconds. Three curve calibration methods, straight line, polygon, and quadratic fit, suit each element, while single-point calibration keeps linearity within 2%. Microprocessor control automates calibration and measurement steps that older analog models leave to the operator. An air compressor and LPG fittings ship as standard, with an optional thermal printer and software. Clinical labs run serum electrolyte panels, agricultural labs test soil and plant calcium and potassium, food, beverage, and pharmaceutical QC teams check mineral content, and environmental and industrial labs analyze water and process samples. LPG cylinders are a running requirement here, so confirm the storage and refill arrangements before comparing the Spectrophotometer category and Flame Photometer range.



Quantity:
$2978
Ions Measured K, Na, ca
Element Detection Limit 3 elements
Measurement Range K: 0 – 100 ppm
Na: 0 – 100 ppm
Li: 0 – 100 ppm
Ca: 0 – 1000 ppm
Ba: 0 – 1000 ppm
Stability 15s ≤ 3%
Linear Error K: 0.2 ppm
Na: 0.5 ppm
Li: 0.1 ppm
Ca: 2 ppm
Ba: 8 ppm
Minimum Detection Limit K: 0.1 ppm
Na: 0.1 ppm
Li: 0.1 ppm
Ca: 2 ppm
Ba: 8 ppm
Curve Calibration Straight line method, Polygon method, Quadratic fit
Linearity 2% (single point CAL)
Display LCD
Feature AreaDescription
FlameQuick flame stabilization.
Air SupplyBuilt-in air compressor.
Ion AnalysisMulti-ion analysis for potassium, sodium, and calcium.
CalibrationStraight line, polygon, and quadratic fit curve calibration methods.
OptionsOptional thermal printer and software.

LPG Reducing Valve

1 piece

Stainless steel bellows for LPG

1 piece

Silica gel tubing for waste liquid

1 piece

PU tubing for air

1 piece

Air Compressor

1 piece

1.

 Built in thermal Printer

2.

Software
  • Supports analysing serum potassium, sodium, and calcium for routine electrolyte checks in clinical laboratories.
  • Handles testing soil and plant calcium and potassium in agriculture.
  • Suited to measuring mineral content in food and beverage products.
  • Applied to checking sodium, potassium, and calcium content in pharmaceutical quality control.
  • Employed for analysing water and process samples in environmental and industrial laboratories.
  • Fits LPG-fuelled bench work with the standard air compressor and LPG fittings.

Frequently Asked Questions

The Flame Photometer EZL-FP143 is widely used to measure sodium, potassium, calcium, and lithium concentrations in liquid samples. These measurements are critical in clinical diagnostics for monitoring electrolyte balance in blood and serum. The instrument is also used in agriculture to evaluate soil fertility and fertilizer quality. In the food and beverage industry, it helps monitor mineral content for product safety and nutritional labelling, thus serves as a versatile solution for clinical, environmental, agricultural, and industrial laboratories.

Our Flame Photometer EZL-FP143 is designed with user convenience as a priority. Its clear touch screen and intuitive controls make it simple to set up tests and view results quickly. The system supports easy calibration and direct concentration display, which reduces operator error. Our design ensures even less experienced users can generate accurate results with minimal training. This efficiency makes it ideal for busy laboratories where routine testing must be both fast and reliable.

The Flame Photometer EZL-FP143 is designed with multiple safety features to ensure secure operation in laboratories. It includes a gas leak alarm, flameout protection, and automatic gas shut off, which safeguard both the user and the instrument. These protections reduce the risk of fire hazards and accidents during analysis. Our system is also built to operate reliably under routine conditions, offering peace of mind to laboratory staff. When combined with standard laboratory safety protocols, it provides a safe and dependable testing platform.

Our Flame Photometer EZL-FP143 requires only minimal maintenance to ensure long-term performance. Regular cleaning of the nebulizer and sample aspiration system helps prevent blockages that could affect accuracy. Our recommendation is to check gas connections and perform periodic calibration to maintain consistent results. Keeping the instrument in a clean, dust-free, and ventilated area also extends its lifespan. With these simple steps, laboratories can rely on for years of accurate and dependable service.

Ezialb’s Flame Photometer EZL-FP143 is equipped with USB connectivity, optional printer support, and multilingual operation to simplify data management. These features allow laboratories to transfer, store, and share results easily, reducing time spent on manual documentation. The ability to store standard curves and test sets further streamlines workflow. Our system ensures that data is both accessible and well-organized for compliance and reporting.