EziLab offers the UV-Visible Spectrophotometer EZL-US117, a single beam UV meter with deuterium and tungsten-halogen lamps and a silicon photodiode detector. A 1200 lines/mm grating scans 190–1100 nm at a fixed 2 nm bandwidth with ±0.5 nm wavelength tolerance, while photometric readings span -0.3 to 3 A and 0–200 %T at ±0.5 %T. Stray light stays at or below 0.05 %T at 220 and 360 nm, drift holds within ±0.002 A per hour at 500 nm, and baseline flatness sits at ±0.0015 A. A four-position cell holder takes sample sets, the dot-matrix LCD and solvent-resistant alphanumeric keypad run fully automated scans, USB and parallel ports feed PCs and printers, while the pre-aligned deuterium lamp swaps out without adjustment. Pharmaceutical QC departments, biochemistry labs, clinical chemistry units, water testing stations, teaching colleges and general research groups use this UV-Vis spectrophotometer for daily absorbance work. Common tasks include API assay by absorbance, protein and nucleic acid estimation, colorimetric water tests, enzyme activity reads and student practical sessions. Choose it over the double beam sibling when budget and simplicity outrank long-run baseline tracking. Single beam means re-zeroing on the blank each time the wavelength changes, a step to time against any method that reads at several wavelengths. Compare it with Spectrophotometer listings, where Single Beam UV-Visible Spectrophotometer holds its closest relatives.



Wavelength Range 190 nm – 1100 nm
Spectral Bandwidth 2 nm
Optical System Single beam (1200 lines/mm grating)
Wavelength Accuracy ±0.5 nm
Wavelength Repeatability ±0.5 nm
Photometric Display Range -0.3 – 3A, 0 – 200%T, 0 – 9999C
Photometric Accuracy ±0.5%T
Photometric Repeatability 0.3%T
Stability ±0.002A/h @ 500 nm
Baseline Flatness ±0.0015A
Stray Light ≤0.05%T @ 220 nm, 360 nm
Noise ±0.001A
Cell Holder 4 single cell holder
Display LCD (128×64 Dots)
Lamps Deuterium and Tungsten Halogen lamps
Detector Silicon photodiode
Data Output Port USB
Printer Port Parallel port
Packing Dimension (W×D×H) 57×45×31 cm
Gross Weight 13 Kg
Feature AreaDescription
Compact OpticsCompact optics scan across the full wavelength range of the instrument.
Lamp ReplacementA pre-aligned deuterium lamp can be swapped without tools.
Keypad EntryA solvent-resistant keypad with alphanumeric entry handles names and units.
USB StorageUSB data output and storage move results to a PC.
Single-Beam OperationSingle-beam operation keeps the build simple, with re-zeroing on the blank after a wavelength change.
  • Supports API assay work in pharma labs.
  • Handles protein and nucleic acid estimation in biochemistry labs.
  • Suited to enzyme activity reads in clinical labs.
  • Applied to colorimetric water testing in QC labs.
  • Employed for general research absorbance work.