EziLab offers the Auto Chemistry Analyzer EZL-CA102, a clinical chemistry analyzer running 200 tests per hour with 49 sample positions and 56 reagent positions on a refrigerated tray. Post-spectral photometry reads eight wavelengths from 340 to 700 nm across 120 reusable 6 mm cuvettes held at 37°C. Sample volumes run from 2 to 70 µl. Automatic cuvette washing, interior and exterior probe washing, independent stirring, and crash detection keep runs moving. The analyzer handles serum, plasma, urine, and body fluids, with STAT priority for urgent samples. Listed reagent kits cover glucose, cholesterol, triglycerides, ALT, AST, creatinine, urea, uric acid, bilirubin, alkaline phosphatase, LDH, CPK, albumin, HbA1c, and RF, so this biochemistry analyzer supports liver, kidney, lipid, cardiac, and diabetes panels. Linear and non-linear calibration plus real-time QC with Westgard rules and cumulative sum checks keep results traceable. Hospital and clinical labs use this blood chemistry analyzer for routine metabolic panels, and bidirectional HL7 LIS links over LAN send orders and results without manual entry. Biology and histopathology laboratories process body fluid samples, while research institutes run custom assays across 56 reagent positions. Growing mid-volume labs gain the most. Three numbers to check: 200 tests per hour, 49 sample positions and 56 reagent positions; the Analyzer category and Chemistry Analyzer range list the same figures for other models.



Quantity:
$8800
Throughput 200 tests/hour
Sample Volume 2-70 µl
Reagent Volume 20-350 µl
Sample Positions 49 sample positions
Reagent Positions 56 reagent positions
Wavelength 340,405,450,510,546,578,630,700nm
Absorbance 0~3.0 Abs
Humidity 30-80%
Washing Automatic cuvettes washing
Probe Washing Automatic washing interior and exterior
Reagent Cooling Refrigerated tray with independent switch
Cuvettes 120 reusable cuvettes, optical length 6mm
Mixed Probe Independent stirring
Stat Function Yes
Light Source 12V/30W halogen lamp
Spectrophotometry Post-spectral spectrophotometry
Calibration Linear: K factor, 1-point, 2-point and multipoint linearNon-Linear: Spline, Polygon, Index, Logarithm, Logit-4P,Logit-5
Quality Control Real-time QC, Westward multi rule, Cumulative sum check, Twin Plot(2D)
Software Windows 7/8/10 LIS system available
LIS System Bi-direction, support HL7 protocol
Interface LAN port access
Printer External, multiple reporting mode available
Temperature 10 - 30°C
Temperature Control 37±0.1°C, real time monitor
Water Consumption Deionized water: 5 L/H
External Dimension (W×D×H) 950x612x510 mm
Package Dimension (W×D×H) 1118x728x1151 mm
Net Weight 75 kg
Gross Weight 130 kg
Feature AreaDescription
Throughput and VolumeRuns 200 tests per hour with 2 to 70 µL sample volume and 20 to 350 µL reagent volume.
Positions49 sample positions and 56 reagent positions, with a refrigerated tray on a separate switch.
PhotometryPost-spectral measurement at 8 wavelengths from 340 to 700 nm with a 12V/30W halogen lamp.
Cuvettes and Washing120 reusable cuvettes with 6 mm optical length, automatic cuvette washing and interior and exterior probe washing.
Calibration and QCLinear and non-linear calibration, with real-time QC including Westgard multirule.
  • Applied by hospitals for routine metabolic panels on serum and plasma at 200 tests per hour.
  • Employed by clinical labs for liver, kidney and lipid panels using 8 wavelengths from 340 to 700 nm.
  • Suited to diabetes and cardiac testing for glucose, HbA1c, CPK and LDH on a refrigerated 56-position reagent tray.
  • Supports research institutes running custom assays with linear and non-linear calibration.
  • Handles STAT testing in mid-volume labs with 49 sample positions.
  • Fits labs linked to a LIS through bidirectional HL7 over LAN.
ReagentQuantity
Glucose100 ml (40 × 2, 20 × 1)
T cholesterol100 ml (40 × 2, 20 × 1)
ASAT125 ml (50 × 2, 25 × 1)
ALAT100 ml (40 × 2, 20 × 1)
Creatine120 ml (45 × 2, 15 × 2)
A Urique100 ml (40 × 2, 20 × 1)
Urea UV100 ml (40 × 2, 20 × 1)
HDL cholesterol120 ml (45 × 2, 15 × 2)
LDL cholesterol120 ml (45 × 2, 15 × 2)
Direct bilirebine100 ml (40 × 2, 20 × 1)
Total bilirubine100 ml (40 × 2, 20 × 1)
Phosphate Alcaline100 ml (40 × 2, 20 × 1)
LDH100 ml (40 × 2, 20 × 1)
CPK100 ml (40 × 2, 20 × 1)
Albumine120 ml (40 × 3)
HBA1c cnt120 ml (45 × 2, 15 × 2)
RF 120 ml (45 × 2, 15 × 2)
Trigliceride100 ml (40 × 2, 20 × 1)