EziLab offers the Biological Indicator Incubator EZL-BI101, a mini incubator that controls temperature from room temperature plus 5°C up to 100°C, holding uniformity and stability within 0.3°C with a 0.1°C display. It heats from 20°C to 56°C within 6 minutes, and a timer runs from 1 minute to 99 hours. A digital control panel, over-temperature protection, and safety alarms fit a 145 by 113 by 110 mm body weighing 0.5 kg. Optional blocks for 9, 10, 12, 15, and 16 mm tubes accept common self-contained biological indicators, so staff can incubate each autoclave spore test right beside the sterilizer. The fast climb to 56°C suits Geobacillus stearothermophilus spores used for steam cycles, and lower setpoints cover other indicator organisms. Pairing each sterilization indicator result with a timed incubation supports documented sterility testing. Hospital central sterile departments run spore checks on steam sterilizers without mailing indicators to an outside lab, and surgical centers verify loads before release. Pharmaceutical plants use it to validate sterilizer cycles for media and equipment, while research laboratories confirm autoclave performance on glassware and biohazard waste. Its small footprint fits a crowded prep bench. Rather than buying a second mini unit by default, check whether a larger Laboratory Incubator or an added Biological Indicator Incubator fits your daily indicator count.



Quantity:
$1152
Temperature Control Range Room Temperature + 5℃ to 100℃
Temperature Accuracy ≤ ± 0.3℃
Temperature Uniformity ≤ ± 0.3℃
Temperature Stability ± 0.3℃
Display Accuracy 0.1℃
Timing Range 1 minute to 99 hours
Heating Time ≤ 6 minutes (20℃ to 56℃)
Dimensions 145 × 113 × 110 mm
Weight 0.5 Kg
Feature AreaDescription
Temperature RangeControls temperature from room temperature + 5 °C up to 100 °C.
Heating TimeHeats from 20 °C to 56 °C in 6 minutes or less.
TimerTiming range from 1 minute to 99 hours.
Control and SafetyDigital control panel with over-temperature protection and safety alarms.
Tube BlocksOptional blocks for 9, 10, 12, 15 and 16 mm test tubes.
  • 10 mm × 15 Test tubes Block × 1 Piece 12 mm × 12 Test tubes Block × 1 Piece 15 mm × 6 Test tubes Block × 1 Piece 16 mm × 6 Test tubes Block × 1 Piece 9 mm × 18 Test tubes Block × 1 Piece

  • Applied by hospital central sterile departments for in-house spore checks on steam sterilizers.
  • Employed by surgical centers verifying loads before release, with heating from 20 to 56 °C in 6 min or less.
  • Suited to pharmaceutical plants checking sterilizer cycles for media and equipment with a 1 min to 99 h timer.
  • Supports research labs confirming autoclave performance on glassware and biohazard waste.
  • Handles Geobacillus stearothermophilus spore indicators at 56 °C in tube blocks from 9 to 16 mm.
  • Fits benches beside an autoclave for self-contained biological indicators, in a 145 × 113 × 110 mm body.