EziLab’s Humidity Control Anaerobic Incubator EZL-HI81 holds oxygen below 0.1%, CO2 from 0 to 20%, and humidity from 50% to 90% RH inside a 420 x 300 x 500 mm interior chamber, with dual operation modes and an airlock cycle under 5 minutes to move samples in and out without breaking anaerobic conditions. Built-in UV sterilization, oxygen monitoring, and over-temperature protection support anaerobic maintenance beyond 13 hours between airlock cycles, while the 950 x 680 x 750 mm operation chamber holds enough labware for batch work. As an anaerobic chamber built for oxygen-sensitive organisms, this unit supports strict anaerobes alongside microaerophiles that need controlled CO2 and humidity together. Clinical microbiology labs use it for stool, wound, and blood cultures targeting anaerobic pathogens, while gut microbiota research relies on the same co2 incubator settings for mixed populations. Biochemistry labs apply the humidity range to protein and enzyme work sensitive to drying, and environmental studies use the chamber for soil and sediment cultures. Academic microbiology departments favor a combined lab incubator and glovebox setup like this one over separate anaerobic jars for higher throughput. See the Laboratory Incubator and Humidity Control Anaerobic Incubator pages for further specifications and ordering details.



Quantity:
$18678
O2 Control Range Less than 0.1%
Airlock Cycle Time Less than 5 minutes
Operation Chamber Cycle Time Less than 1hr
Anaerobic maintenance time Greater than 13hrs
Temperature Range RT+3 to 60°C
Temperature Stability < ± 0.3°C
Temperature Uniformity < ± 1 °C
CO2 Range 0 to 20 %
CO2 Control Accuracy ±0.1% (imported sensor)
Humidity Control Range 50 to 90%RH
Humidity Fluctuation ±3%RH
Power Rating 1500W
Interior Chamber Dimension (W×D×H) 420 × 300 × 500 mm
Operation Chamber Dimension (W×D×H) 950 × 680 × 750 mm
Exterior Dimension (W×D×H) 1450 × 740 × 1420 mm
Feature AreaDescription
OxygenO2 control range of less than 0.1%, with anaerobic maintenance time of more than 13 hours and real-time oxygen monitoring.
Cycle TimesAirlock cycle time of less than 5 minutes and operation chamber cycle time of less than 1 hour.
TemperatureTemperature range of RT+3 to 60 °C.
CO2 and HumidityCO2 range of 0 to 20% and humidity control range of 50 to 90% RH.
ProtectionUV sterilization and over-temperature protection.
  • Applied by clinical microbiology labs for stool, wound and blood cultures held under oxygen below 0.1%.
  • Employed by gut microbiota researchers for mixed cultures that need CO2 from 0 to 20%.
  • Suited to protein and enzyme work sensitive to drying, using the 50 to 90% RH humidity range.
  • Supports soil and sediment cultures incubated from RT+3 to 60 °C.
  • Handles anaerobic research runs that rely on a 13-hour hold without gas resupply and an airlock cycle under 5 minutes.
  • Fits academic labs that want real-time oxygen monitoring and UV sterilization around a 420 × 300 × 500 mm interior.