UV-Visible Spectrophotometer EZL-US123 offers a wavelength range of 190 to 1100nm. It features an 8-inch color touchscreen for easy operation and clear data display. The system supports full-spectrum scanning, kinetic studies, multi-wavelength measurements, and linear regression. It includes a power protection system and large memory for storing results and equations. Our UV-Visible Spectrophotometer well-suited for pharmaceutical quality testing, biochemical research, and chemical analysis.
| Wavelength Range | 190 to 1100 nm |
|---|---|
| Optical System | Double Beam |
| Bandwidth Options | 1.8 nm |
| Wavelength Accuracy | ± 0.3 nm |
| Wavelength Repeatability | Less than or equal to 0.3 nm |
| Photometric Accuracy | ± 0.3 %T ± 0.002 Abs (0 to 0.5A) ; ± 0.004 Abs (0.5 to 1.0 A) |
| Photometric Repeatability | Less than or equal to 0.15 % T 0.001 Abs (0-.0.5 A) 0.002 Abs (0.5-1.0A) |
| Photometric Range | 0.0–200%(Transmittance)-0.301-4.000 (Absorbance) 0.000-9999 ( Concentration) |
| Stray Light | Less than or equal to 0.003 % T at 220 nm & 360 nm |
| Grating | 1200 lines / Cell |
| Detector | Silicon Photocell |
| Display | 8-inch Touch Screen |
| Power Requirements | AC 220 V ± 22V 50Hz ± 1 Hz 200W |
| Packaging Size | 710 × 5900 × 550nm , 36Kg |
Large data memory
Large data memory
Power Protection Design
Double beam system
USB connectivity port
Operational Manual | 1 piece |
1 cm Glass Cuvette | 4 pieces |
1 cm Quartz Cuvette | 2 pieces |
Power Cord | 1 piece |
Fuse | 2 pieces |
1 | UV WIN8 Spectrum Data Processing Software |
UV-Visible Spectrophotometer EZL-US123 is used for accurate qualitative and quantitative analysis in pharmaceuticals, biotechnology, and chemical industries. It is also applied in environmental monitoring, food safety testing, and academic research laboratories.
The UV-Visible Spectrophotometer EZL-US123 Double Beam improves accuracy by measuring the sample and reference simultaneously, which minimizes errors caused by light source fluctuations or external conditions. Its optical system ensures stable baseline performance, which is crucial for long-term experiments. This makes the instrument especially effective for precise quantitative analysis in clinical, pharmaceutical, and research labs. The consistent performance helps laboratories achieve reproducible results even in demanding applications.
Our UV-Visible Spectrophotometer EZL-US123 Double Beam is suitable for a wide range of applications, from protein and nucleic acid quantification to chemical compound analysis. Environmental laboratories use it for water testing and pollutant detection, while pharmaceutical labs rely on it for quality control of raw materials and formulations. The instrument is equally valuable in teaching and research institutions where accurate and reliable spectral analysis is required. It can meet both routine and advanced testing needs.
Ezilab’s UV-Visible Spectrophotometer EZL-US123 Double Beam is built with usability in mind, offering intuitive controls and a clear display for smooth operation. Ezilab’s software interface allows users to set up methods, run tests, and interpret results with minimal training. This makes it practical for busy labs where multiple technicians may operate the system. Routine checks and calibration are simple, helping to keep workflows uninterrupted. The overall design ensures efficiency and ease of use in daily laboratory operations.
The UV-Visible Spectrophotometer EZL-US123 Double Beam is designed with durability and stability as priorities. Its dual-beam configuration continuously corrects for lamp fluctuations, ensuring more accurate readings over time. Ezilab’s high-quality components help minimize measurement drift, making it dependable for extended studies and repeated testing. Regular calibration is straightforward, allowing labs to maintain reliable performance without lengthy downtime. This makes a strong long-term investment for laboratories seeking stable results.
The UV-Visible Spectrophotometer EZL-US1223 Double Beam requires only basic routine care to stay in top condition. Cleaning cuvettes, keeping the sample compartment dust-free, and running periodic calibration checks are the primary tasks. Ezilab’s design minimizes the need for frequent technical servicing, which reduces downtime and maintenance costs. Replacement consumables and parts are easily accessible, allowing smooth operation when components need attention. With proper care it can deliver reliable results for many years.
The UV-Visible Spectrophotometer EZL-US123 Double Beam offers advantages that single-beam systems cannot match. By measuring both sample and reference simultaneously, it eliminates errors caused by environmental changes and light source instability. Its double-beam design also reduces the need for repeated recalibration, saving valuable time in high-throughput labs. For applications where precision and reproducibility are critical, such as pharmaceuticals and advanced research, this level of accuracy is indispensable.