EziLab offers the High Speed Refrigerated Centrifuge EZL-HRC103, a PRP centrifuge that reaches 16,000 rpm and 27,648 g RCF while refrigeration holds the rotor chamber between -20 and 40 °C within ±2 °C. Rotors carry six 250 mL bottles, a frequency-conversion drive holds speed to ±10 rpm, and run times program from one second to 99 hours 59 minutes. The controller stores 100 programs, logs and processes run data on board, and an Ethernet port streams records to lab networks. Over-speed and over-temperature protection stop the drive before rotor or sample limits are crossed, and noise stays at or below 65 dB(A) on 3,500 W. At 180 kg and 850 mm tall it stands on the floor beside processing lines. Blood banks, transfusion services, regenerative medicine manufacturers, diagnostic laboratories, biotechnology companies and research institutes use this high speed refrigerated centrifuge for cold, high-g separations. Typical runs include platelet-rich plasma preparation, buffy coat isolation, plasma fractionation, bacterial cell pelleting, protein precipitate collection and lipoprotein separation. Choose it over the 10,000 rpm sibling when assays call for higher g-force on mid-size bottles. Platelet-rich plasma work calls for gentle starts and stops; ask whether acceleration and braking can be set per program before treating the 100 stored programs as enough. Skim Laboratory Centrifuge for the wider field, then read rotor tables on High Speed Refrigerated Centrifuge pages.



Quantity:
$9449
Maximum Speed 16000 rpm
Maximum RCF 27648 × g
Maximum Capacity 6 × 250 ml
Timer Range Optional: 1min to 99h59min and 1s to 99min59s
Default: 1s to 99min59s
Speed Accuracy ±10 rpm
Temperature Range -20°C to 40°C
Temperature Accuracy ±2°C
Noise Level ≤65dB (A)
Power Consumption 3500 W
Dimensions (L × W × H) 730 × 590 × 850 mm
Weight 180 kg
Feature AreaDescription
Program MemoryStored programs recall run settings for repeat spins.
Network PortA built-in ethernet interface connects the unit to a network.
Data HandlingData storage and processing are supported on the unit.
DriveFrequency conversion technology drives the rotor.
ProtectionOver-speed and over-temperature protection watch each run.
  • Supports platelet-rich plasma preparation in blood banks and transfusion services.
  • Handles buffy coat isolation and plasma fractionation in laboratories.
  • Suited to regenerative medicine production work with stored programs and a network port.
  • Applied to pelleting bacterial cells and collecting protein precipitates in biotechnology companies.
  • Employed for lipoprotein separation in research institutes.