EziLab offers the Low Speed Refrigerated Centrifuge EZL-LRC102, a compact floor cold centrifuge that spins four 750 mL bottles at up to 5,350 rpm and 5,030 g while a high-performance compressor holds the chamber anywhere from -20 to 40 °C within ±1 °C. Speed holds to ±10 rpm, the timer runs to 99 hours 59 minutes, user programs store repeat methods, and aluminum alloy rotors keep mass low. Door lock malfunction protection stops a run if the latch fails, the cooling circuit uses an eco-friendly agent, noise stays at or under 65 dB(A), and the 120 kg cabinet draws only 1,700 W from one socket. Cell culture laboratories, research institutions, clinical laboratories, pharmaceutical process rooms, blood collection centers and biotechnology companies use this low speed refrigerated centrifuge where loads must stay cold through gentle spins. Typical runs include culture medium harvesting, cell washing in 750 mL bottles, blood bag component separation, serum and plasma pooling, precipitate collection and vaccine bulk clarification. Choose it over the 6-liter sibling when four bottles per run are enough. Aluminum alloy rotors can pit under salt buffers and some disinfectants; ask which cleaners are approved and when to inspect the rotor. Weighing four bottles against a larger bottle count is easiest across Laboratory Centrifuge and Low Speed Refrigerated Centrifuge entries.



Quantity:
$7565
Maximum Speed 5350 rpm
Maximum RCF 5030 × g
Maximum Capacity 4 × 750 ml
Timer Range 1s to 99min59s or 1min to 99h59min
Speed Accuracy ±10 rpm
Temperature Range ˗20°C to 40°C
Temperature Accuracy ±1.0°C
Noise Level ≤65dB (A)
Power Consumption 1700 W
Dimensions (L × W × H) 660 × 560 × 850 mm
Weight 120 kg
  • Supports user-defined programs

  • Rotors built of aluminum alloy

  • High performance compressor unit

  • Protection for door lock malfunction

  • Employs an eco-friendly cooling agent

•Harvests culture medium and washes cells for cell culture labs, loading four 750 mL bottles per run.
•Separates blood components for blood collection centers, with the chamber cooled between -20 °C and 40 °C and held within ±1.0 °C.
•Pools serum and plasma for clinical labs, recalling user-defined programs so each routine starts with the same settings.
•Clarifies vaccine bulk for pharmaceutical process rooms at up to 5,030 × g, with door lock malfunction protection built into the cabinet.
•Collects precipitates for research institutions and biotechnology companies, running timers as long as 99 h 59 min in a 660 × 560 × 850 mm floor-standing body.