EziLab offers the Mini Centrifuge EZL-MC112, a two speed microcentrifuge machine that spins at 4000 rpm for 1200 g or 6000 rpm for 2000 g from a brushless DC motor that never needs brushes changed. Three click-on rotors swap without tools: six 1.5 or 2.0 mL tubes, six 0.5 mL tubes, or two to eight 0.2 mL PCR strips. The timer runs 20 seconds to 99 minutes, the lid locks electrically during a run and releases on its own at the end so samples never sit warming, and a start-up self-check reports cumulative run time and the last run’s settings. The unit ships in a 230 by 180 by 160 mm box at 2 kg and takes little bench space. Choose it over the single-rotor PCR plate spinner when microtubes and strips share one bench. Molecular biology labs spin down reagents before PCR, clinical labs collect droplets from tube walls, forensic units process trace samples, and environmental labs settle soil extracts. Routine jobs include quick spins of master mix, pelleting debris from lysates, strip tube collection, and short microtube separations. Mini units begin at Laboratory Centrifuge and continue in Mini Centrifuge; confirm first that the strip rotor fits your strip length and cap style.
| Capacity |
6×1.5/2.0 ml 6×0.5 ml tubes 2-8×0.2 ml PCR strip rotor |
|---|---|
| Dual Speed Options | 4000 rpm & 6000 rpm |
| Maximum RCF |
1200×g (4000 rpm) 2000×g (6000 rpm) |
| Timer | 20 sec to 99 min |
| Packing Dimension (W×D×H) | 230×180×160 mm |
| Gross Weight | 2 Kg |
Easy programming to achieve high accuracy of speed control
Easy operation and intuitive menu and easy to read display
Maintenance free brushless DC motor
Click-on design or effortless interchangeable rotor
Compact, rugged design
Automatic self-diagnosis on startup showing accumulative running time and last running parameters
Lid with electric lock and automatic release function saves processing time and prevents sample over heating
Small foot print for efficient use of lab space
Quick release rotor exchange
| • | Applied by molecular biology labs to spin down reagents before PCR using the 0.2 ml strip rotor. |
| • | Employed by clinical labs to collect droplets from the walls of 1.5 ml and 2.0 ml tubes. |
| • | Suited to forensic units for settling trace samples in small tubes. |
| • | Supports environmental labs preparing soil extracts for further testing. |
| • | Handles 6 x 1.5/2.0 ml or 6 x 0.5 ml tubes in one run with a click-on rotor. |
| • | Fits crowded benches with 4000 or 6000 rpm speed options and a 20 s to 99 min timer. |