EziLab supplies the Horizontal Autoclave EZL-CH81 with a 150L sterilizing chamber, 0.22MPa working pressure, and a 134C working temperature adjustable down to 40C. Sterilization and drying cycles run 0 to 60 minutes, heat average holds within 2C, and 9KW power runs a front-loading cylindrical chamber measuring 440mm by 1000mm, with the unit weighing 240kg net and 320kg gross. A stainless steel interior and exterior resist corrosion, a digital controller pairs temperature with automatic pressure control, and safety features cover over-temperature and over-pressure alarms alongside a door lock holding until pressure drops to 0.027MPa. Clinics and medical laboratories load the chamber with surgical instruments, glassware, and culture media for routine sterilization cycles, while microbiological organizations run repeat batches through the same 150L capacity for media prep and instrument turnaround between test runs. Research institutes rely on the automated drying stage to cut manual handling between cycles, and hospital sterile processing departments use the 9KW/380V power rating to match existing three-phase electrical installations without rewiring. Laboratories across the USA pick mid-capacity horizontal autoclaves like this one when a compact footprint needs to cover both instrument and media sterilization on one bench. Check capacity against the Autoclave and Horizontal Autoclave pages before ordering.



Quantity:
$6850
Sterilizing Chamber Volume 150 L
Working Pressure 0.22MPa
Working Temperature 134°C
Adjustable Temperature Range 40° - 134°C
Sterilization Time 0 – 60 minutes
Drying Time 0 – 60 minutes
Heat Average ≤ ±2°C
Power 9 KW
Chamber Dimension (ɸ×D) 440 ×1000 mm
Dimension (L×W×H) 1400×600×1300 mm
Package Dimension (L×W×H) 1550×750×1850 mm
Net Weight 240 Kg
Gross Weight 320 Kg
Feature AreaDescription
Chamber150 L capacity, Ø440 × 1000 mm
Temperature134 °C working, adjustable from 40 to 134 °C
Pressure0.22 MPa working pressure
DoorFront-loading, silicone gasket, safety door lock
ProtectionOver-temperature, over-pressure, water level cut-off, audible and visible alarms
  • Applied by clinics to sterilize surgical instruments in a 150 L front-loading chamber at 134 °C.
  • Employed by sterile processing departments for routine cycles at 0.22 MPa with an adjustable 40 to 134 °C range.
  • Suited to medical laboratories for glassware turnaround between test runs using 0 to 60 min sterilization and drying times.
  • Supports culture media preparation in microbiology labs within the Ø440 × 1000 mm chamber.
  • Handles hands-off sterilization in research institutes through automated drying.
  • Fits loads that call for a safety door lock plus over-pressure, over-temperature and water level cut-off protection.