EziLab supplies the Vertical Steam Sterilizer EZL-VS97 for hospitals and clinical laboratories that need capacity between the 50L and 100L vertical units in this catalog. At 75L capacity, 134°C, and 0.22MPa with a 0-60 minute cycle, this lab autoclave fills the gap for facilities that have outgrown a 50L vertical installation but don't yet need the full 100L capacity, all while keeping the same space-saving vertical chamber orientation over an equivalent horizontal unit. That 75L capacity gives hospitals and clinics meaningful headroom over the 50L model for growing sterilization volume, while staying well short of the floor space and daily-load assumptions built into the 100L unit — a practical middle step for departments scaling up gradually within the vertical format rather than jumping straight to the largest available vertical capacity. Running at the standard 0.22MPa and 134°C used across this sterilizer line keeps cycle compatibility consistent with other units, so labs running mixed equipment don't need separate validation protocols per machine. Clinical labs with growing but not yet maximal vertical sterilization demand get a capacity tier matched to that specific growth stage. See the Lab Autoclave and Vertical Steam Sterilizer ranges for mid-capacity vertical sterilization needs across USA hospital and clinical laboratory settings.
| Chamber Volume | 75 L |
|---|---|
| Working Pressure | 0.22MPa |
| Maximum Temperature Range | 134°C |
| Working Temperature | 105° - 134°C |
| Maximum Working Pressure | 0.23MPa |
| Heat Average | ≤ ±1°C |
| Timer | 0 – 60 min |
| Power | 3×1.5 KW |
| Chamber Dimension (ɸ×D) | 400×600 mm |
| Overall Dimension (L×W×H) | 560×560×1120 mm |
| Packing Dimension (L×W×H) | 650×630×1280 mm |
| Net Weight | 80 Kg |
| Gross Weight | 100 Kg |
Completely stainless steel structure
Hand wheel type of quick open door structure
Pressure safety lock
LED indicators indicate the working state
Intuitive operation and higher working comfort
Over-temperature and over-pressure auto protection
Double scale indication pressure gauge
Self-inflating type seal
Safe protection during water lack
Automatic shut off with an audible sound after sterilization process
Easy to operate, safe and reliable
Low power consumption
It is designed for easy maintenance
Steam is not allowed to enter chamber when door is open
High energy efficiency and long service life
These devices are widely used in clinical laboratories, pharmaceutical industries, medicine and health care industry, biotechnology, microbiology for effective sterilization of glassware, biological materials, culture and other raw materials and disposables etc.