EziLab offers the Ion Chromatograph EZL-IC64, an anion chromatography system that runs KOH or NaOH gradient elution at up to 42 MPa for water quality anions such as chloride, sulfate, and nitrate. Choose it over the multi-eluent EZL-IC66 when the lab analyzes anions only, since dropping MSA cation capability keeps the system simpler and focused on anion panels. Eluent concentration sets from 0.1 to 100 mM in 0.1 mM steps, letting gradients separate early and late eluting anions. The pump delivers 0.001 to 9.999 mL/min with ≤0.1 MPa pressure display accuracy, and the conductivity detector covers 0 to 50,000 µS/cm with a ≤0.8 µL cell, 0.02 nS electronic noise, and ≤0.001 µS baseline noise and drift. Built-in low pressure degassing removes bubbles that would disturb the baseline, eluent pre-heating stabilizes retention times, and temperature control from 5 to 60°C holds ±1°C. An automatic injection system with automatic dilution handles high-concentration samples without manual prep. Environmental agencies test drinking water, wastewater, and surface water, disease control centers screen public water supplies, food and chemical labs check product anions, and electronics, mining, and metallurgy labs monitor process and rinse water. Count the cation methods on your schedule first, because sodium, ammonium, or calcium work sits outside this anion system and the Chromatograph category and Ion Chromatograph range are where cation-capable models can be compared.
| Cell Volume | ≤0.8 µL |
|---|---|
| Detection Range | 0 to 50000 µS/cm |
| Detection Resolution | ≤0.0020 ns/cm |
| Electronic Noise | 0.02 ns |
| Baseline Noise | ≤0.001 µs |
| Baseline Drift | ≤0.001 µs |
| Pump Maximum Pressure | 42 MPa |
| Pressure display accuracy | ≤0.1 MPa |
| Flow Rate Range | 0.001 to 9.999 mL/min |
| Injector Maximum Pressure | 35 MPa |
| Detector Maximum Pressure | 10.0 MPa |
| Eluent Type | KOH/NaOH |
| Eluent Concentration Range | 0.1 to 100 mM |
| Concentration Increment | 0.1 mM |
| Pressure | 0.1 – 5.0 mL/min |
| Operating Temperature Range | ≤ 30 MPa |
| Temperature Accuracy | 5° to 60°C |
| Power Requirement | ± 1°C |
| Dimension (L×W×H) | 150 W |
| Net Weight | 350×470×650 mm |
| Gross Weight | 34 Kg |
| Feature Area | Description |
| Eluent Pre-Heating | Eluent pre-heating before the column. |
| Degassing | Built-in low pressure degassing that removes bubble interference. |
| Automatic Injection | Automatic injection system with automatic dilution. |
| Display | Large colour LCD screen. |
| Gradient Elution | KOH or NaOH eluent for gradient elution. |