EziLab offers the Dry Bath Incubator EZL-DBI111, a cool dry block heater with lid controlling from 25 °C below room temperature up to 100 °C with ±0.3 °C accuracy at 37 °C. The heated lid sits up to 10 °C above the block to stop condensation, the block climbs from 25 °C to 100 °C in 12 minutes, programs hold five steps and repeat up to 99 cycles, and a 4 °C hold keeps samples cold after a run. Blocks swap without tools and the unit reads which one is fitted, with formats for 35 tubes of 2.0 or 1.5 mL, 54 of 0.5 mL, 96 PCR tubes, or a plate. Power draw is 150 W, the body measures 300 by 200 by 210 mm at 4.7 kg. Choose it over the heat-only siblings when ligations or cold shocks need sub-ambient steps. Molecular biology labs run restriction digests on it, clinical labs incubate serology tubes, biotech firms hold enzymes cold between steps, and university labs stage PCR preps. Routine tasks include DNA denaturation, hybridization, and cold enzyme reactions. Blocks are separate purchases; confirm your plate profile and tube brand fit before choosing between the 35-tube and 96-position formats. Heating-only and deeper-cooling alternatives are one level down from Laboratory Incubator, at Dry Bath Incubator.



Quantity:
$1955
Temperature Setting Range -10℃ to 100℃
Temperature Control Range Room temperature - 25℃ to 100℃
Temperature Accuracy ≤ ± 0.3℃ at 37℃
Temperature Uniformity ≤ ± 0.3℃ at 37℃
Display Accuracy 0.1℃
Heating Lid Temperature Setting Range OFF to + 10℃
Heating Lid Temperature Accuracy ≤ ± 0.5℃
Timing Range 1 second to 99 minutes 59 seconds
Heating Time ≤ 12 minutes (from 25℃ to 100℃)
Heating Lid Heating Time ≤ 10 minutes (from 25℃ to 100℃)
Cooling Time 1 ≤ 12 minutes (from 100℃ to 25℃)
Cooling Time 2 ≤ 25 minutes (from Room temperature to Room temperature - 30℃)
Storage at 4℃ Yes
Multi Points Running Yes (maximum 5 points)
Multi Cycle Yes (maximum 99 times)
Fuse 250 V 3A ⌀ 5 × 20
Power Consumption 150 W
Dimensions 300 × 200 × 210 mm
Weight 4.7 Kg
Feature AreaDescription
Heating LidAdjustable heating lid that limits condensation on tube caps.
Temperature RangeHeating and cooling below room temperature for warm and cold incubation.
Block IdentificationAutomatic block identification with optional tube and plate blocks.
ProgramsMulti-point programs with repeat cycles and a cold hold after a run.
DisplayLCD screen with a temperature sensor for monitoring.
  • 2.0 ml × 35 Centrifuge Tubes Block × 1 Piece 1.5 ml × 35 Centrifuge Tubes Block × 1 Piece 0.5 ml × 54 Centrifuge Tubes Block × 1 Piece 0.2 ml × 96 PCR Centrifuge Tubes Block × 1 Piece 0.2 ml × 96 ELISA Plate Tubes Block × 1 Piece

  • Supports serology tube incubation and cold sample holds in clinical labs.
  • Handles restriction digests and ligations in biotech firms.
  • Suited to PCR preparation with the heated lid in molecular biology labs.
  • Applied to DNA denaturation and hybridization using multi-step programs.
  • Employed for cold enzyme reactions, enzyme holds and cold shocks.